REPORT 3933 US ROUTE 11

FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0.

CORTLAND, NEW YORK 13045

Project No. G100346803

Date: June 1, 2011

REPORT NO. 100346803CRT-017 TEST OF ONE LED PAR30 LAMP MODEL NO. LP10562FL4D

RENDERED TO LITETRONICS INTERNATIONAL INC. 4101 WEST 123RD STREET ALSIP, IL 60803

TEST:

Electrical and Photometric tests as required to the IESNA test standard.

LABORATORY NOTE: The laboratory that conducted the testing detailed in this report has been Qualified, Verified, and Recognized for LM-79 Testing for ENERGY STAR for SSL by US DOE's CALiPER program. STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. AUTHORIZATION:

The testing performed was authorized by signed quote number 500287913.

STANDARDS USED:

The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen:

IESNA LM-79: 2008

Approved Method for Electrical and Photometric Measurements of Solid-State Lighting Products

ANSI NEMA ANSLG C78.377: 2008 Specifications of the Chromaticity of Solid State Lighting Products

DESCRIPTION OF SAMPLE:

The client submitted one sample of model number LP10562FL4D. The sample was received by Intertek on May 2, 2011, in undamaged condition, and one sample was tested as received. The sample designation was L11874L.

DATES OF TESTS:

May 23, 2011 through May 25, 2011.

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Measurement uncertainty budgets have been determined for applicable test methods and are available upon request.

SUMMARY Model No.: Description:

LP10562FL4D 10W PAR30 MED 120V FL 3000K 50,000H DIM

Criteria Total Lumen Output (lm) Total Power (W) Luminaire Efficacy (lm/W) Power Factor Current ATHD (%) Color Rendering Index (CRI) -Ra Duv Correlated Color Temperature (CCT) Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u’) Chromaticity Coordinate (v’)

Sphere 564.7 10.21 55.31 0.964 20.80 82.2 0.003 2993 K 0.433 0.396 0.252 0.518

Result Distribution 518.7 10.24 50.65 0.966

EQUIPMENT LIST Equipment Used

Leeds & Northup Standard Resistor Data Precision Digital Voltmeter Fluke Multimeter Fluke Temperature Meter Kikusui DC Power Supply Sorenson DC Power Supply NIST Spectral Flux Standard Source Elgar AC Power Supply Yokogawa Power Meter LSI High Speed Mirror Goniometer Cole Parmer Hygro Thermometer Xitron Power Analyzer ITS 2 Meter Sphere Fluke Temp Meter Elgar Power Supply

Report No. 100346803CRT-017

Model Number

Control Number

Last Calibration Date

Manganin 3600 45 52 35-10L DLM150-20E

Y089 V124 M133 T801 E160 --

02/17/11 02/17/11 02/17/11 06/11/10 -----

RF1024

---

09/18/10

CW1251 WT210 6440 445703 2503AH W/ CDS 600 53 II CW1251

-E464 -T1357 E235 N308 N1324 NA

-04/19/11 w/use 10/12/10 04/20/11 w/use 03/11/11 NA

page 2 of 7

Calibration Due Date

02/17/12 02/17/12 02/17/12 06/11/11 ----100 hours of use -04/19/12 w/use 10/12/11 04/20/12 w/use 03/11/12 NA

Date: June 1, 2011

TEST METHODS Seasoning in Sample Orientation – LED Products No seasoning was performed in accordance with IESNA LM-79.

Photometric and Electrical measurements – Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software.

Photometric and Electrical Measurements – Integrating Sphere Method A Labsphere Model DAS 1100 Diode Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology.

Estimated Total Operating Time Model No. LP10562FL4D

Report No. 100346803CRT-017

Total Hours 3

page 3 of 7

Date: June 1, 2011

RESULTS OF TESTS Spectral Distribution over Visible Wavelengths nm

mW/nm

nm

350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455

0.245 0.228 0.221 0.198 0.184 0.184 0.146 0.181 0.124 0.169 0.115 0.135 0.205 0.384 0.748 1.359 2.164 3.058 4.017 5.001 5.460 5.012

460 465 470 475 480 485 490 495 500 505 510 515 520 525 530 535 540 545 550 555 560 565

mW/nm nm LP10562FL4D 3.969 570 3.068 575 2.482 580 2.076 585 1.808 590 1.701 595 1.749 600 1.946 605 2.351 610 2.877 615 3.512 620 4.188 625 4.850 630 5.442 635 5.962 640 6.404 645 6.799 650 7.160 655 7.494 660 7.860 665 8.193 670 8.512 675

mW/nm

nm

mW/nm

8.821 9.149 9.440 9.731 10.030 10.229 10.417 10.484 10.517 10.459 10.333 10.086 9.760 9.354 8.888 8.415 7.895 7.350 6.822 6.267 5.701 5.185

680 685 690 695 700 705 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780

4.693 4.217 3.793 3.371 2.994 2.662 2.346 2.058 1.819 1.596 1.414 1.234 1.082 0.958 0.851 0.749 0.666 0.576 0.512 0.469 0.424

LITETRONICS Sample No. L11874L Model No. LP10562FL4D Spectral Data Over Visible Wavelengths 12.000

(mW/nm)

10.000 8.000 6.000 4.000 2.000 0.000 350

400

450

500

550

600

650

700

750

800

Nanometers

Report No. 100346803CRT-017

page 4 of 7

Date: June 1, 2011

RESULTS OF TESTS (cont’d) Photometric and Electrical Measurements at 25°C – I ntegrating Sphere Method

Intertek Sample No.

Correlated Color Temperature (K)

CRI Ra

CRI R9

L11874L

2993

82.2

25.6

CIE 31’ Chromaticity Coordinate DUV (x) LP10562FL4D 0.003 0.433

CIE 31’ Chromaticity Coordinate (y)

CIE 76’ Chromaticity Coordinate (u’)

CIE 76’ Chromaticity Coordinate (v’)

0.396

0.252

0.518

Input Power Factor

Current ATHD (%)

Absolute Luminous Flux (Lumens)

Lumen Efficacy (Lumens Per Watt)

0.964

20.80

564.7

55.31

Base Orientation

Input Voltage Input Current Input Power Input Power (Vac) (mA) (Watts) Factor

Absolute Luminous Flux (Lumens)

Lumen Efficacy (Lumens Per Watt)

UP

LP10562FL4D 88.26 10.24

518.7

50.65

Intertek Sample No.

Base Orientation

Input Voltage (Vac)

L11874L

UP

120.0

Input Current (mA)

88.3

Input Power (Watts)

LP10562FL4D 10.21

Photometric and Electrical Measurements – Distribution Method

Intertek Sample No.

L11874L

120.0

0.966

Intensity (Candlepower) Summary at 25°C - Candelas Angle

0

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

1550 1610 1624 1100 277 183 114 69 37 22 16 8 7 5 3 1 0 0 0

22.5 45 L11874L 1550 1550 1624 1643 1628 1577 1074 1001 272 264 181 180 114 113 67 66 36 35 21 21 15 15 8 8 6 7 5 5 3 3 1 1 0 0 0 0 0 0

Report No. 100346803CRT-017

67.5

90

1550 1665 1515 875 256 174 111 64 35 20 15 8 6 5 2 1 0 0 0

1550 1726 1507 772 251 172 108 62 33 19 14 8 6 5 2 1 0 0 0

page 5 of 7

Date: June 1, 2011

RESULTS OF TESTS (cont’d) Illumination Plots Model No.: LP10562FL4D Mounting Height: 10 ft. Illuminance - Cone of Light

Isoillumination Plot

Zonal Lumen Summary and Percentages at 25°C Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180

Lumens LP10562FL4D 449.8 489.6 513.6 5.2 518.7 0.0 518.7

% Luminaire 86.7 94.4 99.0 1.0 100.0 0.0 100.0

Reflector Summary

Efficiency (%) Field (10%): Beam (50%): Total:

78.7 54.9 100.1

Report No. 100346803CRT-017

Lumens LP10562FL4D 408.1 285.0 519.0

page 6 of 7

Horizontal Spread (°)

Vertical Spread (°)

47.3 26.4

48.9 29.3

Date: June 1, 2011

Pictures (not to scale)

CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report.

In Charge Of Tests:

Report Reviewed By:

Kenda Branch Engineer Lighting Division

Jeffrey Davis Associate Engineer Lighting Division

Attachment: None

Report No. 100346803CRT-017

page 7 of 7