General Notes
Block A Units: F-39
C
Copyright Stephen Davy Peter Smith Architects 2013
All dimensions are given in millimetres, and internal dimensions are taken to face of structure. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work. All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers. All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.
WM
FG
DW
All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
P6
FG
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.
DW
1310(AS)11-01
Bathroom
72 1033
M&E
72
P1
D07 A8
Kitchen/Living/Dining
72
75
-
4297 2792.5
Comment
By
Date
stephen davy architects peter smith
72
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
Double 11.7sqm
W
D
P1
Kitchen amended CF 10.02.14 Tenure Defined. Bathroom & Kitchen types WB 06.09.13 added, Tile backer board added to Bathroom, Doors amended where bubbled to allow for 300nib, Issued for Construction Issued for Tender WB 28.06.13
Rev
72
D
Client Water butt
Outlet
P RW
Durkan Ltd Durkan House 214 - 224 High Street Waltham Cross Hertfordshire EN8 7DU Outlet
2010.5
Partition Reference Refer to drawing 1310(AS)07-03
B A
26.3sqm
P1
Bedroom 2432.5
Future Hoist
P≠
Wall Tile Backing Board Refer to drawing 1310(AS)07-03
D06 A8
P RW
RWP
973
W
72 8.8sqm
103 72
72
0.6sqm
D05 A8
Door Reference D≠ : Door No /xx: Unit Type Refer to door schedules, series 1310(AS)08-XX.
916(s/o)
D04 A8
72
Store
916(s/o)
2890.5
65.5
840(s/o)
710
72
W
104
D03 A8
72 288
D02 A8
840(s/o)
1193.5
1125.5
P5
134.5
P2
0.8sqm
916(s/o)
D≠ xx
72 905.5
72 P2
D01 A8
Key / Notes Entrance door openings: Refer to the G.A. floor plans. Also to be read in conjunction with door schedules, drawing series 1310(AS)08-XX.
1310(AS)10-02
P3
2122.5
1109
Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
Kitchen Type A7
916(s/o)
4.6sqm
P1
D
AOV 1700 x 951 1.5m2 min
WM
Bathroom Type 01a
F/F
AOV/access hatch above
2372.5
P3a
B
Project
Union Road Union Road / Clapham Road Clapham SW4 Drawing Title
Flat Layout Drawings-Shared Ownership Flat Type A8 2B3P - 61.5sqm Job No.
Drawn By
Date
Checked by
1310
June 2013 Drawing No.
WB
Scale
1:50 @ A3
GD/KK
1310(GA)406
Revision B