General Notes

Block A Units: F-03, F-22

C

Copyright Stephen Davy Peter Smith Architects 2013

All dimensions are given in millimetres, and internal dimensions are taken to face of structure. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work. FG

DW

All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers. All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.

WM 1835

Bathroom Type 02c 1310(AS)11-02

Bathroom

F/F

4.6sqm

Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.

2442.5 P2a

916(s/o)

376

940

Store

0.8sqm

0.5sqm

72

51

840(s/o)

Key / Notes

P1

Entrance door openings: Refer to the G.A. floor plans. Also to be read in conjunction with door schedules, drawing series 1310(AS)08-XX.

P2

1360.5

Future Hoist

916(s/o)

47 840(s/o)

Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.

72

D02 A3

72

D03 A3

D04 A3

D01 A3

D≠ xx

Door Reference D≠ : Door No /xx: Unit Type Refer to door schedules, series 1310(AS)08-XX.

P≠

Partition Reference Refer to drawing 1310(AS)07-03

P1

D06 A3

Kitchen/Living/Dining 3073

1270.5

72

-

Broom cupboard added to kitchen CF 10.02.14 Tenure Defined. Bathroom & Kitchen types WB 06.09.13 added, Tile backer board added to Bathroom, Doors amended where bubbled to allow for 300nib, Issued for Construction Issued for Tender WB 28.06.13

Rev

Comment

By

Date

P1

Double

4210.5

4210.5

24sqm

B A

W

WM

916(s/o)

Wall Tile Backing Board Refer to drawing 1310(AS)07-03

72

82

D05 A3

72

M&E

P2

700

916

1825.5

916

B 72

72

678.5

P1

This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.

12sqm

stephen davy architects peter smith DW

1310(AS)10-01

P3a

72

2674

Kitchen Type A3

All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work.

FG

2072.5

DW

Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail: [email protected] Website: www.davysmitharchitects.co.uk

D

2945.5

Client

4.4sqm

Balcony

P RW

Durkan Ltd Durkan House 214 - 224 High Street Waltham Cross Hertfordshire EN8 7DU Project

Union Road Union Road / Clapham Road Clapham SW4 Drawing Title

Flat Layout Drawings-Shared Ownership Flat Type A3 1B2P - 49sqm Job No.

Drawn By

Date

Checked by

1310

June 2013 Drawing No.

WB

Scale

1:50 @ A3

GD/KK

1310(GA)402