eztag3 | proximity and keypad door entry - Sparks Electrical Wholesalers


[PDF]eztag3 | proximity and keypad door entry - Sparks Electrical Wholesalershttps://04646a9cf351cc0d3888-b8b406d15fe93f790abb5bf0e9ab7ab3.ssl.cf3.rac...

2 downloads 157 Views 2MB Size

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 1

E Z TAG 3 | P R OX I M I T Y A N D K E Y PA D D O O R E N T RY

USER MANUAL

www.espuk.com

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 2

System Components

Proximity and Keypad Reader

10 x Proximity Tags

1 x Hex Key 4 x Plastic wall plug 4 x Countersunk screws 1 x Diode and 1 x Capacitor

Optional Accessories

EVBPSBB Lock Power Supply

2

EV-EXIT Push to Release

EV-EBG EV-ML-250/500XT Emergency Release Electro-magnetic Lock

ENTERD Electric Lock

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 3

Contents Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 EZTAG3 Wiring Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 EZTAG3 Wiring Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Advanced Programming Guide How to set-up Access Pin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 How to set-up Access Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Deleting Access Pin or Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Changing Programming Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Clear all Pin and Tag Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Default to Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Lock 1 Output Operating Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Enable ‘Door Bell’ Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Enable ‘Tamper Alarm’ facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Access Pin Number for Lock 2 Output . . . . . . . . . . . . . . . . . . . . . . . . 10 Deleting Access Pin for Lock 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Lock Output Operating Time for Lock 2 Output . . . . . . . . . . . . . . . . 11 System setup record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

3

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 4

Installation

Release hex screw from the bottom of the keypad

(Side View) Push the keypad up to release from mount plate

Thread system cable through the cable entry hole then make the system connections (as per the wiring diagram), mount the bracket to the surface and slide the keypad to the mountplate, re-fit the hex screw to secure into position.

Note: if using more than one keypad, ensure that the keypads are mounted a minimum 185cm apart

4

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 5

EZTAG3 Wiring Example 1 Indication LEDs

Electro-magnetic lock

Electronic lock

_ +

Capacitor for Electro-magnetic lock Diode for Electronic Lock

Keypad

Lock -release time NC

4 3

N.C for Electro-magnetic lock N.O for Electronic lock

+ _ + _

Red Black Green Purple Grey Pink

Tag Reader

EZTAG3 Wiring Example 2 Indication LEDs Red

Input DC:

Black

Input AC:

Green

N.O

Purple

COM

Blue

Keypad

+12V - +24V or 12V - 24V

N.C

Output for Lock 1 (Volt-free)

Grey Orange Pink Green/White

N.O

Purple/White

COM

Blue/White

Push button for Lock 1 (N.O)

P.b for Lock 2 (N.O)

N.C

Output for Lock 2 (Volt-free)

Yellow White

+ _

Speaker connection for ‘door bell’ facility (8ȍ 0.5w recommended)

Tag Reader

5

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 6

How to set-up Access Pin Number Step Number 1

Enter Programming

2

9

3 4

Keypad Indication

Action

0

1

2

3

4

1

2

3

Long Tone

4

(Default)

Long Tone

2

Enter a starting location number

?

0 0 0

9 9 9

Enter a 4 digit pin

5

?

?

?

6

#

#

To end programming

Double e Tone Long Tone

(1234 not be used)

How to set-up Access Tags Tags Step Number 1

Enter Programming

2

9

3 4 5 6 7

0

2

3

4

1

2

3

4

(Default)

?

Long Tone

Long Tone

Enter a unused location number*

?

1

5

?

0 0 0

9 9 9

Long Tone

Enter number of tags to be registered

Tone T one

Present the tag with the lowest serial number

Tone T one

All other batch tags will auto register

*Each tag will use up a location number 6

Keypad Indication

Action

#

#

To end programming

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 7

Deleting Access Pin or T Tag ag Step Number

Keypad Indication

Action

1

Enter Programming

1

2

Enter the location number of tag/pin

0 0 0

3 4

2

3

4

1

2

3

4

(Default)

Long Tone

9 9 9

To delete

#

#

To end programming

Changing Programming Pin Step Number

Keypad Indication

Action

1

Enter Programming

2

3

1

2

3

4

1

2

(Default)

3

?

?

?

?

Enter new 4 digit programming pin

4

?

?

?

?

Re-enter new 4 digit programming pin

5

#

#

To end programming

3

4

Long Tone

Long Tone

Note; To access keypad’s programming mode, the 4 digit programming code is entered in twice

7

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 8

Clear all Pin and Tag Tag Data Step Number

Keypad Indication

Action

1

Enter Programming

2

8

3

8

8

4

#

#

1

2

3

4

1

2

3

4

(Default)

Long Tone

Long Tone To o end programming

Default to Factory Settings Step Number

8

Keypad Indication

Action

1

Enter Programming

2

8

3

9

9

4

#

#

1

2

3

4

1

(Default)

2

3

4

Long Tone

Long Tone To o end programming

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 9

Lock 1 Output Operating Time Step Number 1

Enter Programming

2

1

3 4

Keypad Indication

Action

Enter number of seconds 00-99

#

#

1

2

3

4

1

2

3

4

(Default)

?

Long Tone

Long Tone

?

To end programming

Enable ‘Door Bell’ Facility Step Number

Keypad Indication

Action

1

Enter Programming

2

2

1

2

3

4

1

2

3

4

(Default)

3

0

2

To o enable

4

#

#

To end programming

0

1

To disable

Long Tone

Long Tone

Becomes the ‘door bell’ push in normal mode

9

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 10

Enable ‘Tamper Alarm’ facility Step Number

Keypad Indication

Action

1

Enter Programming

2

6

1

2

3

4

1

2

3

4

(Default)

3

0

2

To o enable

0

1

4

#

#

To end programming

To disable

Long Tone

Long Tone

Tamper alarm activates the keypad’s internal buzzer and ‘door bell’ output if the light sensor is exposed

Access Pin Number for Lock 2 Outputt Step Number 1

Enter Programming

2

9

3 4

10

Keypad Indication

Action

0

1

2

3

4

1

2

(Default)

3

4

Long Tone

Long Tone

3

Enter an unused location number

0 0

0 9

ter a 4 digit pin ? En (1234 should not be used)

5

?

?

?

6

#

#

To end programming

Double e Tone Long Tone

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 11

Deleting Access Pin for Lock 2 Step Number

Action

1

Enter Programming

2

4

3

2

3

4

1

2

3

4

(Default)

Enter the location number of pin

4 5

1

Keypad Indication Long Tone

0 9

0 0

To delete

#

#

To end programming

Lock Output Operating Time for Lockk 2 Output Step Number 1

Enter Programming

4

1

2

3

4

1

(Default)

2

3

4

Long Tone

5

2 3

Keypad Indication

Action

Enter number of seconds 00-99

#

#

?

?

Long Tone

To end programming

11

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 12

To assist in future programming, it is recommended that a record is made of the system setup. System Location Number (000-999)

12

Tag Serial Number

Tag Owner

Notes

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 13

System Location Number (000-999)

Tag Serial Number

Tag Owner

Notes

13

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 14

User Guide To release Lock 1 (A) Enter a programmed Access Pin number

To access programming mode (B) Present a registered tag

1

2

3

4

1

2

3

4

(Default)

Technical Specification DC input

12 - 24volts

Working temperature

AC input

12 - 24volts

Reader frequency

125KHz

Standby current

80ma

IP rating

65

Dimension

150 x 44 x 24mm

Operating current (without lock) 110ma

14

-20c to +50c

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 15

15

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 16

Telephone: 01527 51 51 50 Fax: 01527 51 51 43 email: [email protected]

Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN

E&OE - Errors and omissions excepted. L15

www.espuk.com