Core A
General Notes
Core C
C
300 34 EQ
42.5
EQ
FLOOR
42.5
Entrance Lobbies Core C 1:5
EQ
34 EQ
76 EQ
FLOOR
Typical Sign Height 1:10
42.5 EQ
FLATS
All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.
22 22 22 22
22
30
34 EQ
FLOOR
22
76
42.5
EQ
FLATS
46
6th 5th 4th 3rd 2nd 1st
11-12
34-35 36-40
09-10 07-08
This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
05-06 03-04
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.
01-02
01-05
Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
All Signage drawings to be read in conjuction with each other: 1310(AS)12/04 - 1310(AS)12/13
22
34 EQ
76 EQ
42.5 EQ
FLOOR
FLATS
5th 4th 3rd 2nd
13-14
46
12-15
105 EQ
30
Entrance Lobbies Core D 1:5
16-18
All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work.
Key
22 22
04-07
22
282
22
08-11
22
22
03 01-02
09-12 05-08 01-04
30
22
22 22 22 22 22 22 22 22 22 22
06-10
2nd Floor
300
30
22
11-15
FLATS
Core D
EQ
42.5
5th 4th 3rd 2nd 1st Grd
16-20
FLOOR
All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.
1500
105 EQ
22
326
22
01-06
21-25
30
42.5
5th 4th 3rd 2nd Grd
22
07-12
300
370
EQ
22
22 22
13-16
30
22
22
22
238
4th 3rd 2nd
Core B Entrance Lobbies Core B 1:5
105
Copyright Stephen Davy Peter Smith Architects 2014
All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.
46
FLATS
46
22
76
30
EQ
30
Entrance Lobbies Core A 1:5
105
22
42.5
300
Rev
Comment
By
Date
CONSTRUCTION 220 42 EQ
FFL
01-03 04-06 TYPICAL SIGNAGE DETAILS Typical Lift Sign All Floors 1:5 300 216
300 42
30
Stair / Elevator / Exit Direction 1:5
STAIRS 150
22 30
82
30 30
BIKE STORE A
240
30
Brushed stainless steel plate, edges rounded, 2 mm thick, sizes as shown, Text, number engraved 0.5 mm and blackened, Font: Arial, Text and arrow centred
Durkan Ltd Durkan House 214-224 High Street Waltham Cross Hertfordshire EN8 7DU Project Title
Union Road Union Road / Clapham Road Clapham SW4 Drawing Title
30
42
22 12 22 12 22
83
30
134
30
300 83
116
Client
30
Flats 01-06
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
2nd Floor
22
151
18 11 18 22
22
2nd Floor
Typical Stair Sign All Floors 1:5
22 12 22
30
30
30
EQ
160
30
30
151
136
15122 18 11 18
42
Stephen Davy Peter Smith Architects
220
ELEVATOR & STAIRS
Typical Signage Details Note: Drawings are indicative only. Sub-contractor to submit shop drawings prior to fabrication. Signage to comply with all relevant British Standards.
Job No.
Drawn By
Date
Checked by
1310
Oct 2014 Drawing No.
AM
Scale 1:5/1:10 @ A3
GD
1310(AS)12/04
Revision -