TWNSHP 08, RNG 11, TRACT SALISHAN HOMESITE #271-A, ACRES 0.32, DOC201002363 Tax Lot # 271-A: SALISHAN 311 SALISHAN DR Gleneden Beach, OR 97367 NEW CONC. PLANTER

OWNER: NEIGHBOR'S HOUSE

SALISHAN LEASEHOLDERS INC FRERES TRISHA L TRUSTEE & FRERES T KYLE TRUSTEE, LEASE 10483 SILVER FALLS HWY SE AUMSVILLE, OR 97325

NEIGHBOR'S DECK AND WALK

pacific ocean

CONTRACTOR:

10FT

Name phone: Email:

SIDEY ARD

N75° SETB

ACK L

RELOCATED 1500 GAL. COMBINATION SUMP/ SEPTK TANK - LOW PRESSURE SEEPAGE BED

24'W , 67.2

EXISTING 1500 GAL. COMBINATION SUMP/ SEPTK TANK - LOW PRESSURE SEEPAGE BED

4'

INE

EXISTING ELEC. TRANSFORMER

ARCHITECT:

Union Station Suite #304 800 NW 6th Avenue Portland, Oregon 97209 503-227-2140 WWW.NATHANGOODARCHITECT.COM

Nathan Good Architects PC

LEGAL DESCRIPTION & ADDRESS:

Lydia Peters (project manager) phone: 503-560-4355 email: [email protected]

NEW SECOND FLOOR DECK

STRUCTURAL ENGINEER: John Nordling

NEW FRONT PORCH NEW REBUILT WEST DECK (MAIN FLOOR)

phone: 503-924-5901
 email: [email protected]

EXISTING CONCRETE STEPS TO BE REMOVED

NEW CONCRETE STEPS TO GRADE

NEW ENTRY WALK

DEVELOPMENT STANDARDS:

NEW PARKING

Oregon State Building Code as defined in ORS 455.010

NEW SKYLIGHTS LOCATION

NEW ROOF EXTENSION

SETB

ACK

N75°

24'W , 100

.4'

10FT FRO

Site information concerning existing conditions are suitable for preparation of the Drawings and given for convenience to the Contractor. Owner and Architect do not guarantee accuracy of such information. It is the responsibility of the Contractor to inform himself and the necessary officials as to the conditions affecting the Work.

80'

The Work shall conform to the Contract Documents, Oregon Residential Specialty Code (latest addition), and all applicable local building codes. The Contract Documents include Architectural and Engineering Drawings, Specifications if applicable, and any Addendums to the afore mentioned. The intent of the Contract Documents is to include all items necessary for the completion of the Work. Work not covered in the Contract Documents will not be required unless it is reasonably inferable as being necessary to produce the intended results. Damaged or defective work shall be immediately repaired or replaced to the approval of the Architect and at no additional cost to the Owner.

Contractor shall verify all dimensions and field conditions before proceeding and notify Architect of any discrepancies. Contractor shall provide adequate bracing and shoring as necessary until permanent supports and stiffeners are installed. Contractor shall notify the Architect and Owner of proposed field changes prior to construction of modification. Contractor will notify the Owner, Architect, Engineer, and the local building official at critical construction milestones established by the local municipality in order to obtain necessary approvals prior to commencement of work. Contractor will obtain inspections per ORSC R109 and special inspections from an independent testing lab as required by the local municipality. The Architect and Engineers have not been retained or compensated to provide design and/ or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform his/ her work. The undertaking of periodic site visits by the Architect or Engineer shall not be construed as supervision of actual construction nor make either responsible for providing a safe place for the performance of work by the Contractor or the Contractor's employees or employees of suppliers or subcontractors, or for access, visits, use, work, travel, or occupance by any person. Contractor shall take all reasonable precautions for the safety of, and shall provide all reasonable protection to prevent damage, injury or loss to: 1. Employees and all other affected persons. 2. All work, materials, and equipment. 3. Other property at the site or adjacent thereto.

NEW DECK OVER NEW GARAGE ADDITION EXISTING RETAINING WALL EXISTING EDGE OF CONCRETE

PLAN NORTH

SALI

Dimensions shall be to face of framing or face of concrete unless otherwise indicated. Written dimensions take precedence over drawing scale. Do not scale drawings.

EXISTING WATER SERVICE

NT SETBA CK

GENERAL NOTES:

NEIGHBOR'S DECK AND WALK

LOT 271

SALISHAN LEASEHOLDERS INC 10483 SILVER FALLS HWY SE AUMSVILL, OREGON 97325

SIDEY ARD

FRERES RESIDENCE

10FT

DRAINFIELD

NEW OUTDOOR FIREPLACE

RIVE

20-FT 20-FT 10-FT 10-FT

N7°18'E,

Required Setbacks Front Yard** Side Yard (adjacent to street)

Side Yard (interior) Rear Yard

ND

Nordling Structural Engineers LLC 6775 SW 111TH AVE

Beaverton, OR 97008

PR CO N ELI N OT MIN ST RU FO AR CT R Y IO N

LOT 271-A

SHA

Nathan Good Architects, P.C. Union Station Suite @304 800 NW 6th Avenue Portland, Oregon 97209

SCALE: 1" = 10' 0

BUILDING SITE

5'

10'

20'

DRAWN BY: STATUS:

FSG PERMIT

REVISION:

N/A

ENERGY & INDOOR AIR QUALITY NOTES: Exterior joints around windows and door frames, openings between walls and foundations, between walls and roof, openings at penetrations of utilities through walls, floors, and roofs, and all other such openings in the building envelope shall be sealed, caulked, gasketed, or weather-stripped to limit air infiltration. Recessed lighting fixtures installed in the building envelope shall comply with the requirements of ORSC N1104.2.6. IC fixtures are required where adjacent insulation is other than closed cell spray foam. All Kitchens, Laundry Rooms and Bathrooms shall have the appropriately sized spot exhaust fan. Thermal breaks shall be provided between all footings and concrete slabs associated with conditioned spaces.

PRINTED

7/15/13

A1 COVER SHEET & NOTES