Installation Instructions


[PDF]Installation Instructions - Rackcdn.comhttps://a89b8e4143ca50438f09-7c1706ba3fabeeda794725d88e4f5e57.ssl.cf2.rackcd...

74 downloads 175 Views 90KB Size

ISL-28 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1.

CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is supplied to the unit.

2.

CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnecting the unit connector.

3.

CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly.

4.

DO NOT USE OUTDOORS. The ISL-28 is for use with grounded, UL Listed, indoor fixtures except in heated air outlets or hazardous locations.

5.

The ISL-28 requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused A.C. lead.

6.

Do not mount near gas or electric heaters.

7.

The ISL-28 should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

8.

The ISL-28 will cold strike and operate for 90 minutes one 2′ to 4′ T5 or T8 linear lamp.

9.

The ISL-28 is compatible with all A.C. magnetic and electronic ballasts including multiple lamp ballasts with one lamp operating in the emergency mode.

10.

The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

11.

Do not use this equipment for other than intended use.

12.

Install in accordance with the National Electrical Code and local regulations.

13.

Installation and servicing should be performed by qualified personnel.

14.

Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatability before final installation.

SAVE THESE INSTRUCTIONS

THIS UNIT CONTAINS A RECHARGEABLE NICKELCADMIUM BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY.

INSTALLATION INSTRUCTIONS CAUTION: Before installing, make certain the A.C. power is off and the ISL-28 unit connector is disconnected.

1. LAMPS OPERATED

The ISL-28 can be used with most 2′-4′ lamps. Refer to the chart below for the type of lamp(s) operated and the number of lamps to be operated in emergency mode.

OPTION 1

LAMP TYPE 2 FT T5-T12 Single, Bipin

EMERGENCY OPERATION

*VIOLET LEADS

WIRING DIAGRAMS

One Lamp

Connected

1, 2, 3, 4, 5, 6, 7, 8, 9

4 FT T5(28W) T8-T12 Disconnected 1, 2, 3, 4, 5, 6, 7, 8, 9 One Lamp Single, Bipin *The 6″ violet leads provide the lamp selection option. The unit is shipped from the factory with the leads disconnected and capped. 2

2. MOUNTING THE ISL-28

Remove the ballast channel cover. Mount the ISL-28 in the ballast channel at least 1/2″ away from the A.C. ballast(s).

When battery packs are remote mounted, the remote distance can not exceed 1/2 of the distance from ballast to lamp specified by the A.C. ballast manufacturer. For example, if the A.C. ballast manufacturer recommends no more than 25′ remote distance, then the battery pack should not exceed 121/2′. Under no circumstances should the battery pack exceed a distance of 50′ from the lamp.

3. WIRING Refer to the wiring diagrams on the back page for the appropriate wiring of lamp(s) and ballast. Install in accordance with the National Electrical Code and local regulations. For additional wiring diagrams consult Customer Service.

4. INSTALLING THE THREADED BODY TEST SWITCH (TBTS) Recessed Troffer Fixture – Select a convenient location with proper clearance in the ballast cover and drill or punch a 7/8″ hole (1/2″ knockout). Insert the 7/8″ bushing into the hole. Push the plastic tube through the bushing. Route the leads of the TBTS through the plastic tube. Connect the LED wires from the unit to the TBTS (Red/Black or Red w/tag to Red, White/Red to White). Push the entire assembly back into the tube until the lens collar rests against the plastic tube. The plastic tube should be adjusted so that the TBTS is within ¼″ of the fixture lens. The TBTS must be visible after installation. Refer to Illustration 1. Linear Fixture – Select a convenient location on the fixture so the TBTS can be seen after installation. Allow for proper clearance inside the fixture and drill or punch a 1/2″ hole. Remove the nut from the TBTS. Push the TBTS housing into the 1/2″ hole and secure with the nut. Connect the LED wires from the unit to the TBTS (Red/Black or Red w/tag to Red, White/Red to White). Refer to Illustration 2.

Illustration 1

Illustration 2 Recessed Troffer Fixture

Linear Fixture FIXTURE TBTS

FIXTURE BALLAST CHANNEL COVER

ISL-28 PLASTIC TUBE

WHITE LEAD

7/8" BUSHING TBTS

ISL-28 FIXTURE LENS

+ RED LEAD

OBSERVE PROPER POLARITY

Page 2

5. WIRING THE A.C. INPUT A. The ISL-28 and A.C. ballast must be on the same branch circuit. B. The ISL-28 requires an unswitched A.C. power source of either 120 or 277 volts. Select the proper voltage lead and cap the unused lead. C. When the ISL-28 is used with a switched fixture, the A.C. input to the ISL-28 must be connected ahead of the fixture switch. Refer to Illustration 3 for switched and unswitched fixture wiring diagrams.

6. BALLAST WIRING BLOCK DIAGRAM Illustration 3

Switched Fixture

Unswitched Fixture

BLACK

WALL SWITCH

WHITE

BLACK

A.C. BALLAST

WHITE HOT A.C. LINE

HOT A.C. LINE



WHT/BLK

WHT/BLK

(277V) ORG

(277V) ORG

(120V) BLK WHT

COMMON WHT

TBTS

A.C. BALLAST

WHT/RED

(+) RED



ISL-28 TBTS

WHT

➀ Select proper voltage lead. Cap unused lead.

ISL-28

WHT/RED

(+) RED

(+) RED/BLK OR RED W/TAG

(120V) BLK WHT

COMMON

(+) RED/BLK OR RED W/TAG

➀ Select proper voltage lead. Cap unused lead.

6. LABELS Attach the appropriate labels adjacent to the TBTS. Annotate Re-lamping label for lamp type and wattage. The Caution and the Re-lamping labels must be on the fixture in a readily visible location to anyone attempting to service the fixture.

7. COMPLETING INSTALLATION When the installation is complete, switch the A.C. power on and join the ISL-28 unit connector.

OPERATION Normal Mode – A.C. power is present. The A.C. ballast operates the fluorescent lamp(s) as intended. The ISL-28 is in the standby charging mode. The TBTS will be lit providing a visual indication that the battery is being charged. Emergency Mode – The A.C. power fails. The ISL-28 senses the A.C. power failure and automatically switches to the Emergency Mode. One lamp is illuminated, at reduced output, for a minimum of 90 minutes. When the A.C. power is restored, the ISL-28 switches the system back to the Normal Mode and resumes battery charging. See page 1 of the Instruction Manual.

TESTING & MAINTENANCE Pressing the red lens on the TBTS turns off the light on the TBTS and forces the unit into emergency mode, interrupting power to the designated A.C. ballast. The emergency lamp is now being lit by the ISL-28 unit. After releasing the TBTS, the fixture returns to normal operation after a momentary delay. To simulate a “BLACK OUT” use the circuit breaker to turn off A.C. power. Initial Testing – Allow the unit to charge approximately 1 hour, then press the TBTS to conduct a short discharge test. Allow a 24 hour charge before conducting a one hour test. The ISL-28 is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety Code, outlines the following schedule: Monthly – Insure that the TBTS is illuminated. Conduct a 30 second discharge test by depressing the TBTS. One lamp should operate at reduced output. Annually – Insure that the TBTS is illuminated. Conduct a full 11/2 hour discharge test. The unit should operate as intended for the duration of the test. “Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.”

SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL. Consult Customer Service or visit www.iotaengineering.com for current warranty information. Page 3

TYPICAL WIRING DIAGRAMS For wiring diagrams of ballasts not shown, consult our Customer Service.

TBTS TBTS / CHARGE INDICATOR

COMMON



*AC / EMERGENCY

2. TWO LAMP RAPID START BALLAST



TBTS TBTS / CHARGE INDICATOR



COMMON *AC / EMERGENCY

➁ UNIT CONNECTOR

*LAMP LAMP

➀ ➁ ➂

TBTSTBTS / CHARGE INDICATOR COMMON



*AC / EMERGENCY

COMMON

EMERGENCY ISL-28 BALLAST

➁ UNIT CONNECTOR

LAMP

BLK (120V) WHITE WHT/BLK



LAMP TBTSTBTS / CHARGE INDICATOR

*LAMP COMMON *AC / EMERGENCY

Rev. 042407 68428-390

VIOLET

A.C. Ballast

➀ ➁ ➂ ➃

➀ UNSWITCHED

A.C. Ballast

➃ BLUE

LAMP

VIOLET

VIOLET

WHT/RED

ORG (277V)

EMERGENCY ISL-28 BALLAST

➀ UNSWITCHED

BLK (120V) WHITE

COMMON

WHT/BLK

➁ UNIT CONNECTOR

*LAMP



➀ ➁ ➂



TBTS TBTS / CHARGE INDICATOR

COMMON



*AC / EMERGENCY



SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMP OPERATION SECTION FOR VARIOUS OPTIONS. CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

9. THREE LAMP INSTANT START BALLAST BLACK WHITE RED

BLUE

A.C. Ballast

BLUE BLUE



BLUE BLUE/WHT RED/WHT RED YELLOW

SWITCHED OR UNSWITCHED LINE ORG (277V)

EMERGENCY ISL-28 BALLAST

➁ UNIT CONNECTOR

LAMP *LAMP



COMMON

➀ SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

➁ DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED.

➂ LAMP SELECTOR LEADS—REFER

TBTSTBTS / CHARGE INDICATOR

COMMON

➀ UNSWITCHED

BLK (120V) WHITE WHT/BLK



*AC / EMERGENCY

TO INSTALLATION INSTRUCTIONS, LAMP OPERATION SECTION FOR VARIOUS OPTIONS. CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER

➄ TEST ACCESSORY LEADS-

REFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

10. FOUR LAMP INSTANT START BALLAST BLACK WHITE YELLOW

COMMON

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMP OPERATION SECTION FOR VARIOUS OPTIONS. CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER

SWITCHED OR UNSWITCHED LINE

BLUE BLUE/WHT RED/WHT RED YELLOW

VIOLET

BLUE

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

ORG (277V)

RED OR RED/BLK (+) VIOLET

BLUE BLUE BLU/WHT BLU/WHT

BLUE BLUE/WHT RED/WHT RED YELLOW

WHT/RED

WHITE

RED RED ORANGE ORANGE YELLOW YELLOW BROWN BROWN

BLACK WHITE

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS

SWITCHED OR UNSWITCHED LINE

COMMON SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

8. TWO LAMP INSTANT START BALLAST

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

5. THREE LAMP RAPID START BALLAST BLACK



TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

➀ UNSWITCHED

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

5 TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

LAMP







TBTS TBTS / CHARGE INDICATOR

COMMON

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS

BLK (120V) WHITE WHT/BLK

VIOLET

LAMP

EMERGENCY BALLAST ISL-28 VIOLET

RED RED





*AC / EMERGENCY

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

ORG (277V)

RED OR RED/BLK (+)

A.C. Ballast

BLUE BLUE/WHT RED/WHT RED YELLOW

BLUE/WHT BLUE/WHT



5

COMMON

SWITCHED OR UNSWITCHED LINE

WHT/RED

BLACK WHITE BLUE BLUE YELLOW YELLOW

➁ UNIT CONNECTOR

*LAMP

RED

4. THREE LAMP RAPID START BALLAST

LAMP SELECTION LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMP OPERATION SECTION FOR VARIOUS OPTIONS.

➀ UNSWITCHED

BLK (120V) WHITE WHT/BLK

VIOLET



EMERGENCY ISL-28 BALLAST

YELLOW

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

A.C. Ballast

BLUE BLUE RED RED

LAMP LAMP

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED.



BLUE BLUE/WHT RED/WHT RED YELLOW

EMERGENCY

*LAMP

BLK (120V) WHITE WHT/BLK

BALLAST ISL-28

➁ UNIT CONNECTOR

LAMP

LAMP SELECTION LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMP OPERATION SECTION FOR VARIOUS OPTIONS.

SWITCHED OR UNSWITCHED LINE ORG (277V)





VIOLET





ORG (277V)

VIOLET





DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED.

SWITCHED OR UNSWITCHED LINE

BLUE BLUE/WHT RED/WHT RED YELLOW

VIOLET

➀ UNSWITCHED

BLK (120V) WHITE WHT/BLK VIOLET

➁ UNIT CONNECTOR

*LAMP

RED OR RED/BLK (+) VIOLET

LAMP

ISL-28

A.C. Ballast

RED

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

ORG (277V)

EMERGENCY BALLAST

BLACK

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

SWITCHED OR UNSWITCHED LINE

WHT/RED

BLUE BLUE/WHT RED/WHT RED YELLOW

BLUE

RED OR RED/BLK (+)



COMMON

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

7. ONE LAMP INSTANT START BALLAST WHITE

COMMON

3. TWO LAMP RAPID START BALLAST

YELLOW YELLOW



COMMON

RED OR RED/BLK (+)



*AC / EMERGENCY

RED RED



*AC / EMERGENCY

RED OR RED/BLK (+)



TBTS TBTS / CHARGE INDICATOR

BLUE BLUE





RED OR RED/BLK (+) VIOLET





COMMON

A.C. Ballast



TBTSTBTS / CHARGE INDICATOR

WHT/RED

➀ UNSWITCHED

BLK (120V) WHITE WHT/BLK



BLACK WHITE

BLK (120V) WHITE WHT/BLK

LAMP *LAMP

WHT/RED

➁ UNIT CONNECTOR

*LAMP

CONNECTOR

WHT/RED

LAMP

EMERGENCY BALLAST ISL-28

VIOLET

RED RED

ORG (277V)

VIOLET

A.C. Ballast

YELLOW YELLOW

BLUE BLUE/WHT RED/WHT RED YELLOW

WHT/RED

BLUE BLUE

ISL-28

SWITCHED OR UNSWITCHED LINE

RED OR RED/BLK (+)

BLACK WHITE

EMERGENCY BALLAST

LAMP

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

➀ UNSWITCHED

ORG (277V)

➁ UNIT

LAMP

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS





A.C. Ballast

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.





BLU/WHT ORG ORG

SWITCHED OR UNSWITCHED LINE

BLUE BLUE/WHT RED/WHT RED YELLOW

VIOLET

VIOLET



COMMON

WHITE BLU/WHT

YELLOW YELLOW BROWN BROWN BLUE BLUE RED RED

WHT/RED

BLK (120V) WHITE WHT/BLK

VIOLET

➁ UNIT CONNECTOR

*LAMP

UNSWITCHED

EMERGENCY ISL-28 BALLAST

BLACK



ORG (277V)

RED OR RED/BLK (+)

A.C. Ballast

RED RED

BLUE BLUE/WHT RED/WHT RED YELLOW

BLUE BLUE

WHT/RED

BLACK WHITE

6. FOUR LAMP RAPID START BALLAST

SWITCHED OR UNSWITCHED LINE

RED OR RED/BLK (+) VIOLET

1. ONE LAMP RAPID START BALLAST

➀ ➁ ➂

TBTS

TBTS / CHARGE INDICATOR

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

COMMON *AC / EMERGENCY

Page 4

➃ ➄

➀ UNSWITCHED COMMON

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMP OPERATION SECTION FOR VARIOUS OPTIONS. CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

TYPICAL WIRING DIAGRAMS For Osram/Sylvania Rapid Start Ballasts For wiring diagrams of ballasts not shown, consult our Customer Service.



TBTS/CHARGE TBTS INDICATOR

COMMON



*AC / EMERGENCY

LAMP

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

LAMP *LAMP

ORG (277V)

ISL-28 EMERGENCY BALLAST

➁ UNIT CONNECTOR



TBTS TBTS / CHARGE INDICATOR COMMON *AC / EMERGENCY

Rev. 042407 68428-390

BLK (120V) WHITE WHT/BLK

VIOLET

BLUE BLUE

RED OR RED/BLK (+) VIOLET

A.C. Ballast

BLUE BLUE/WHT RED/WHT RED YELLOW



➁ ➂ ➃



TBTS TBTS / CHARGE INDICATOR

COMMON

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.



DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS

➂ ➃

COMMON *AC / EMERGENCY

BLACK WHITE RED RED YELLOW YELLOW

➀ UNSWITCHED COMMON

A.C. Ballast

BLUE/WHT BLUE/WHT BLUE BLUE

BLUE BLUE/WHT RED/WHT RED YELLOW

LAMP







➀ UNSWITCHED

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

4. THREE LAMP RAPID START BALLAST

SWITCHED OR UNSWITCHED LINE

WHT/RED

YELLOW YELLOW

RED RED

BLK (120V) WHITE WHT/BLK

EMERGENCY ISL-28 BALLAST

➁ UNIT CONNECTOR

*LAMP

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

2. TWO LAMP RAPID START BALLAST BLACK WHITE

BLUE BLUE

VIOLET

COMMON

A.C. Ballast

RED OR RED/BLK (+) VIOLET



YELLOW YELLOW

SWITCHED OR UNSWITCHED LINE ORG (277V)

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

LAMP

Page Insert 5

EMERGENCY BALLAST

BLK (120V) WHITE WHT/BLK



TBTSTBTS / CHARGE INDICATOR



➀ ➁ ➂

COMMON *AC / EMERGENCY

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.

ISL-28

➁ UNIT CONNECTOR

*LAMP

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS

SWITCHED OR UNSWITCHED LINE ORG (277V)

VIOLET







➀ UNSWITCHED

BLUE BLUE/WHT RED/WHT RED YELLOW

VIOLET

➁ UNIT CONNECTOR

BLK (120V) WHITE WHT/BLK

RED RED

RED OR RED/BLK (+)

EMERGENCY BALLAST

BLACK WHITE

WHT/RED

ISL-28

VIOLET

*LAMP

ORG (277V)

VIOLET

BLUE BLUE/WHT RED/WHT RED YELLOW

WHT/RED

A.C. Ballast

BLUE BLUE

RED RED

RED OR RED/BLK (+)

BLACK WHITE

3 TWO LAMP RAPID START BALLAST

SWITCHED OR UNSWITCHED LINE

WHT/RED

1. ONE LAMP RAPID START BALLAST



➀ UNSWITCHED COMMON

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS

TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING.