ST01 Series In-Wall Timers Project: Location:

ST01 Series

Product Type:

Digital In-Wall Timers

Contact/Phone:

The ST01 Series In-Wall Timers are easy-to-set, 4-button programmable timers that allow up to 40 event settings per week. The timers have an astronomic feature for sunrise and sunset switching.

Model #:

Features r&BTZUPQSPHSBNGPS)PVSPS%BZMPBEDPOUSPM r"VUP%BZMJHIU4BWJOH5JNFBEKVTUNFOU r$'--&%DPNQBUJCMF r"TUSPOPNJDGFBUVSFQSPWJEFTTVOTFU0/BOETVOSJTF0''TFUUJOHTPS DPNCJOFBTUSPOPNJDGFBUVSFTXJUITQFDJàDUJNFE0/0'' programming r-PXCBUUFSZJOEJDBUPS r$POUJOVPVTMZEJTQMBZTUJNFPGEBZ NPEFBOEMPBETUBUVT r$3MJUIJVNCBUUFSZQSPWJEFTVQUP ZFBSTPGUJNFLFFQJOH XJUIPVU"$QPXFS r3FQMBDFTTJOHMFQPMFPSXBZTXJUDIFTJOBWBSJFUZPGBQQMJDBUJPOT r3BOEPNTFUUJOHGFBUVSFBWBJMBCMFUPBWPJEQSFEJDUBCMFUJNF controlled look r6TFSQSPHSBNTFMFDUJPOTBSFTUPSFEJOOPOWPMBUJMFNFNPSZ r$POUSPMTBMMWPMUBHFGSFRVFODJFTXJUIOPBEKVTUNFOUTSFRVJSFE r/POFVUSBMSFRVJSFE r.BOVBMPWFSSJEFGFBUVSF Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly

Ratings Switch Ratings: 3FTJTUJWF



"NQ 7"$

5VOHTUFO



"NQ 7"$ "NQ 7"$

#BMMBTU



"NQ 7"$ "NQ 7"$

.PUPS



)1 7"$ )1 7"$

%$-PBET



 "NQ 7%$  "NQ 7%$

Warranty:

ST01AC

Limited 1 year

Model Number

Switch

Manual Override

Neutral Required

Battery Backup

Color

ST01C

4JOHMF1PMF8BZ

Yes

/P

Yes

White

ST01AC

4JOHMF1PMF8BZ

Yes

/P

Yes

"MNPOE

XBZBQQMJDBUJPOTVQUPGFFU

Energy Controls

ST01 Series Specification The timer shall be a solid state electronic control, capable of permitting 40 event settings to be distributed through B%BZUJNFQFSJPE QMVTPOF"TUSP0/BOEPOF"TUSP0''TFUQPJOUQFSEBZ5IFUJNFPGEBZFWFOUTFUUJOHTTIBMMCF QSPHSBNNBCMFUPUIFOFBSFTUNJOVUFXJUIBNJOJNVN0/EVSBUJPOPGNJOVUFBOEBNBYJNVN0/EVSBUJPOPGEBZT  IPVST NJOVUFT5IFUJNFSTIBMMIBWFBEJHJUBM-$%SFBEPVUUPTIPXNPEFBOEUJNFPGEBZVTJOHIPVS".1. indicator. The timer shall provide a manual override control for both temporary and permanent overrides. The timer shall PQFSBUFPWFSBUFNQFSBUVSFSBOHFPGž'UPž' ž$UPž$ "MJUIJVNCBUUFSZQSPWJEFTVQUP ZFBSTPGUJNF LFFQJOHXJUIPVU"$QPXFS6TFSQSPHSBNTFMFDUJPOTBSFTUPSFEJOBOPOWPMBUJMFNFNPSZ4XJUDIDPOàHVSBUJPOUPCF 4145XJUIB$4"MJTUFESBUJOHPG3FTJTUJWF IFBUFS "NQ 7"$5VOHTUFO JODBOEFTDFOU "NQ 7"$ "NQ 7"$#BMMBTU áPVSFTDFOU "NQ 7"$"NQ 7"$.PUPS)1 7"$)1 7"$%$ -PBET"NQ 7%$"NQ 7%$5IFUJNFSNVTUàUBTUBOEBSEXBMMCPYBOEBDDFQUBSFDUBOHVMBSEFDPSBUPSXBMM plate. Timer contacts shall make or break current according to user adjustable program. 5IFUJNFSTIBMMCF*OUFSNBUJDNPEFM@@@@@@@@@@@@@@@@@@@@ "MNPOE45"$ 8IJUF45$ 

Diagrams

DIAGRAM 1: TYPICAL EXISTING 2-SWITCH SETUP

LOAD

“COMMON” TERMINAL LINE

WIRE “A” WIRE “C” WIRE “B”

NEUTRAL

3-WAY REMOTE SWITCH

3-WAY MAIN SWITCH

LOAD

DIAGRAM 2: 2-SWITCH SETUP, TIMER INSTALL RE-USING EXISTING REMOTE 3-WAY SWITCH

LINE

BLUE

BLACK

WIRE “B”

TIMER

WIRE “C”

NEUTRAL

JUMPER RED NOT USED

WIRE “A”

3-WAY REMOTE SWITCH

“COMMON” TERMINAL

LOAD

DIAGRAM 3: 2-SWITCH SETUP, TIMER INSTALL USING NEW SINGLE-POLE REMOTE SWITCH

LINE

BLUE

BLACK

WIRE “B”

TIMER

JUMPER RED

WIRE “A”

SINGLE-POLE REMOTE SWITCH

Energy Controls

WIRE “C”

NEUTRAL