LED 30W WALL PACK BULKHEAD FITTING INSTRUCTIONS
These instructions are for the Déluce Lighting 30W LED Wall Pack :
DLLEDSWP30, DLLEDSWP30PC, DLLEDSWP30S, DLLEDSWP30E3 & DLLEDSWP30PCE3 IMPORTANT INSTALLATION INFORMATION • Installation should be carried out in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and taking into consideration the latest Building Regulations. If in doubt, consult a qualified electrician. • Before commencing any installation or maintenance work, ensure electricity is switched off at the mains. • Please take note of the maximum rated voltage for your LED 30W Wall Pack Bulkhead. • Please take note of the IP (Ingress Protection) rating of your LED 30W Wall Pack Bulkhead when deciding it’s location. GENERAL INSTALLATION - SAFETY • Please make sure you are safe when working at height. Employ the latest safety regulations and procedures to ensure the safe installation of this LED 30W Wall Pack Bulkhead.
Fig 1
INSTALLATION INSTRUCTIONS • To achieve the best results from your LED 30W Wall Pack Bulkhead we suggest you take into account the following points before you fit the unit. Do not fix to a surface where vibration is possible or may occur. 1. 2.
3.
Switch off the Mains supply at the main fuse/distribution box, ensuring there is no power to the LED 30W Wall Pack Bulkhead. Mark the position. Using the four fixing hole positions on the back of the base (see Fig 1), then mark the position of the luminaire to the fitting surface. Make sure the fitting surface is suitable to take the weight of the luminaire and is 0.5m from any other surface. Drill the marked 240V~50Hz holes and fit a suitable wall/surface plug (supplied). LED The standard / photocell & sensor models are fitted with 1.5m of cable, make the electrical connections to unit as follows: Product Code Watts
LIVE (Red or Brown) to the terminal marked L NEUTRAL (Black or Blue) to the terminal marked N EARTH - (Green/Yellow) for Class I fittings to Terminal marked
4.
The emergency models are fitted with an additional cable for battery charging, make the electrical connections to unit as follows:
PERMANENT LIVE ((Red or Brown) to the terminal marked PL NEUTRAL (Black or Blue) to the terminal marked N EARTH - (Green/Yellow) for Class I fittings to Terminal marked
DLLEDSWP30 DLLEDSWP30PC DLLEDSWP30S DLLEDSWP30E3 DLLEDSWP30PCE3
Microwave Sensor / Emergency Info 16-25 Lux 30 Lux 12m x 6m 150° 0.5- 3m/s
Hold Time : Battery Pack : Emergency Hours : Emergency Wattage : Charging Time :
25Lux- 50Lux
Microwave Sensor Function 0% Illumination
No movement
100% Illumination
Entering room movement detected
100% Illumination
Leaving room, no movement
0% Illumination after 5 Seconds to 30 Minutes
No movement
IP65 Description
Weight
30W
Standard model
2.0Kg
30W
Photocell model
2.1Kg
30W
Microwave Sensor model
2.1Kg
30W
3 Hour Emergency model
2.5Kg
30W
Emergency + Photocell model
2.6Kg
Specifications
WARNING - THIS FITTING MUST BE EARTHED - Ensure that there are no exposed conductors, loose or trapped cable strands. Luminaire is now ready for use. Connection Light Level : Disconnect Light Level : Detection Zone : Detection Angle : Motion Detection : Daylight Sensor :
Fixing Hole (x4)
90 seconds 14.8V 2200mA 3 hours 10W >24 Hours
Voltage : IP Rating : LED Wattage : Power : Class Rating : Colour Temp : CRI : Flux Luminous : Life Span : Operation Temp : Light Source : Housing Material :
220V-240V~50Hz IP65 30W 34W Class I (requires an Earth) 5000±200K - Daylight >80 2700 Up to 50000 hours -30°C to 40°C Philips LED chip set 3030 Aluminium & Polycarbonate
EMERGENCY VERSION ONLY • LED Indication: Green indicates the battery charging. Ensure Green LED comes on after connecting power, this will turn off when the luminaire is discharging. Ensure batteries are charged for a minimum 24 hours before any testing is carried out.
GUARANTEE
This product is guaranteed in the EU for a period of 1 year from the date of purchase. The guarantee is invalid in the case of improper use, installation, tampering, removal of the QC date label, installation in an improper working environment or installation not according to the current edition of the IEE Wiring Regulations (BS 7671). Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Déluce Lighting does not accept responsibility for any installation costs associated with the replacement of this product. Your statutory rights are not affected. Déluce Lighting reserves the right to alter specifications without prior notice.
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE We recommend this fitting is installed by a qualified Electrician. delucelighting.com • DN4 5FB - UK
DEL0633c/Jan_2017/issue_2/Page 1 of 1