[PDF]LED Power Supply - Rackcdn.comhttps://c761eecbd79071d9c578-5541377ae4e44cfbbc0efe790ed7f783.ssl.cf1.rackcdn...
6 downloads
500 Views
388KB Size
GE Lighting
LED Power Supply Outdoor Dimming Driver GE150/1050/MV-GL 12161
imagination at work
Outdoor Dimming Driver GE150/1050/MV-GL Description: 150W 0.53/0.7/1.05A Dimmable Class 1 PSU Input Voltage: 120-277V Input Frequency: 50-60Hz ROHS Compliant: Yes Max Output Power (W)
150
Output Current (A)
Output Voltage (V)
0.525 ± 5%
Efficiency @ Full Load 120V
230V
277V
140-280
>91%
>92%
>93%
0.700 ± 5%
105-210
>90%
>92%
1.05 ± 5%
70-140
>89%
>91%
Max Input Current (A)
1.60 @ 120V >92% 0.80 @ 277V >91%
20%
Min PF @75W Output
0.9
Max Inrush Current (A/mS)
Protocol Source
See
0-10V
Page 4
Output + (Red)
Line (Black) TVSS Ground (Yellow)
Max THD @75W Output
GE-XXXXX LED Driver
Neutral (White)
Output -1A (Blue) Output -0.7A (Yellow) Output -0.53A (Orange) Dim + (Violet) Dim - (Grey)
Isolated Dimming
Weight (lbs/kg)
IP Rating
0.5mA 100% - 10%
2.2/1
IP66
0-10V
0.5mA 100% - 10%
2.2/1
IP66
0-10V
0.5mA 100% - 10%
2.2/1
IP66
Length in. (cm) Color 12 (30.5) Black (L) 12 (30.5) Yellow (TVSS-GND) 12 (30.5) White (N) 12 (30.5) Violet (+Dim) 12 (30.5) Grey (-Dim) 12 (30.5) Red (+ Output) 12 (30.5) Blue (-1A Output) 12 (30.5) Yellow (-700mA Output) 12 (30.5) Orange (-530mA Output)
Product Features Physical • Unit must be installed within an electrical enclosure. • Enclosure wiring must be rated to 600V & 105°C or higher.
Performance • • • • • • • • • •
Classified as Class 1 as per UL8750. Dimming circuit is classified as Class 2 as stipulated in UL1310. Minimum ambient operating temperature: -40°C. Maximum allowable case temperature: 80°C. For reliability and failure rate information, contact GE Technical Sales Representative. Output current reduces if the case temperature exceeds 85°C. UL listed for operation in dry/damp locations (IP66). Tolerates of extended open circuit and short circuit conditions. Compliant to FCC Title 47 Part 15 Class A Surge resistance per IEEE/ANSI C136.2-2015 Location C-Low (6kV/3kA) • Ground Leakage current of <= 0.4 mA
UL Conditions of Acceptability – E340135 • • • •
The unit has been examined to comply with Class 1 Output Criteria The unit is only to be used in dry or damp locations The metal casing must be connected to EARTH. TVSS-GND (Yellow wire) shall be connected to fixture ground after hi-pot test using closest tab screw. THIS IS NOT A SAFETY GROUND!
Current Dimming Range Range (%)
Technical Information GE150/1050/MV-GL
Lifetime (kHrs) vs Case Temperature (°C 120
Lifetime (KHrs)
100
80
60
40
20
0 35
25
45
55
65
75
85
Driver Case Temperature (°C)
Iout / Iout N (%)
Output current vs Dim Voltage 110 100 90 80 70 60 50 40 30 20 10 0
0.530 A 0.700 A 1.05 A 012345678
91
01
11
2
Vdim (V)
Efficiency vs Output Voltage @ 120V 60Hz 94 Efficiency [%]
92 90 88 86
1050mA
84
700mA 525mA
82 80 0
25
50
75
100
125
150
175
200
225
250
275
300
Output Voltage (V)
Efficiency vs Output Voltage @ 277V 60Hz 94 Efficiency [%]
92 90 88 86
1050mA
84
700mA 525mA
82 80 0
25
50
75
100
125
150
175
Output Voltage (V)
200
225
250
275
300
Technical Information GE150/1050/MV-GL
PF vs Output Voltage @ 120V 60Hz Power Factor
1.000 0.995 0.990
1050mA 700mA
0.985
525mA
0.980 0
25
50
75
100
125
150
175
200
225
250
275
300
Output Voltage
Power Factor
PF vs Output Voltage @ 277V 60Hz 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 0.90
1050mA 700mA 525mA
0
25
50
75
100
125
150
175
200
225
250
275
300
Output Voltage
THD vs Output Voltage @ 120V 60Hz 6
THD %
5 4 3
1050mA
2
700mA
1
525mA
0 0
25
50
75
100
125
150
175
200
225
250
275
300
Output Voltage
THD %
THD vs Output Voltage @ 277V 60Hz 20 18 16 14 12 10 8 6 4 2 0
1050mA 700mA 525mA
0
25
50
75
100
125
150
175
200
225
250
275
300
Output Voltage
Input Inrush Current
Input Ground Leakage Current
Input Voltage [Vrms]
Peak Current Pulse [Apk]
Pulse Duration (50% of Peak) [ms]
Input Voltage [Vrms]
Leakage Current [mA]
120
31
0.1
S1 ON
S1 Off
120
0.18
208
0.18
277
60
0.1
Product Dimensions GE150/1050/MV-GL
MULTIPLE OUTPUT -RED, BLUE, ORANGE, YELLOW LEADS 0.9 [.0]
DIMMING VIOLET, GREY LEADS
10.2 [.4]
38.20 [1.5] 295.5 [11.6]
7.2 [.3]
8.4 [.3]
INPUT BLACK, WHITE LEADS YELLOW TVSS-GND
240.5 [9.5] 211.1 [8.3] 226.2 [8.9] 42.9 59.1 60.7 [1.7] [2.3] [2.4]
4 X R3 [.1]
8.1 [.3]
2 [.1]
207.6 MAX PCB LENGTH [8.2]
6 [.2]
3 [.1] 1 [.0]
55.5 MAX PCB WIDTH [2.2]
1. PUNCH HOLE MIN BEND RADIUS 0.8 MM 2. PART NOMINAL PER 3D DATABASE SUPPLIED AT SAME REVISION AS THIS DRAWING, ONLY CRITICAL DIMENSIONS ARE SHOWN. 3. PART MUST BE FREE OF SHARP EDGES OR BURRS.
PUNCH HOLE
DETAIL A SCALE 4:1
Product Label
(L) BLACK
AVERTISSEMENT !
(TVSS-FGND) YELLOW
RISK OF ELECTRIC SHOC K
Turn power off before servicing. Properly ground power supply and fixture
RISQUE DE CHOC ÉLECTRIQUE IMPORTANT: After HiPot test connect TVSSFGND to fixture using the closest tab screw.
(N) WHITE
VOUT: 70-280V IOUT: 0.53A RED/ORG IOUT: 0.7A RED/YEL IOUT: 1.05A RED/BLU POUT: 150W
Suitable for dry and damp locations tc = 80°C max VDIM: 0-10V
CASE MUST BE GROUNDED
E34013 5
www.gelighting.com GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of the General Electric Company. © 2015 GE. OLP3063 (Rev 09/30/15)
OUTPUT
(+OUT) RED (-OUT_0.53A) ORANGE (-OUT_0.7A) YELLOW (-OUT_1.05A) BLUE (+DIM) VIOLET (-DIM) GRAY
Tc
DIMMING
INPUT
G E150/1050/MV-GL
WARNING /
Déconnectez l’alimentation électeique avant d’installer ce produit .
Measure 20mm down side
LED POWER SUPPLY
VIN nom: 120-230-277V~ Freq: 50/60Hz Iin max: 1.6A~ PF min: 0.9
S/N: sssss yy ddd PWS009 0 Made in China