PDF Format


[PDF]PDF Format - Rackcdn.comc24110ab053e5c234c6f-9b7150e100ab604df0aafbaf58c9fe02.r58.cf3.rackcdn.com/...

0 downloads 112 Views 270KB Size

General Notes C

Privacy screen detail

04 1310(AS)04-31

A3

A4

A5

All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.

07 1310(AS)04-20

65

Ah 381

531

3990

This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers. Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.

03 1310(AS)04-20

P

RW

03 1310(AS)04-20 slab edge

Key

Outlet Water butt

W2

1590

1740 Water butt

W2

1100 65

W01 F-42

Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.

Ag

Outlet

65

4140

2432

Terrace

All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication. All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work.

RWP

3455

W02 F-42

P

RW

P

RW

AS BUILT

1572

651

1422

A05b (h/l) SVP

05 1310(AS)03-12

2515

A9

6402.5

1331

1005(s/o)

Af

Kitchen/Living/Dining

SW5

Bathroom

1310(AS)05-01 P6

TERRACE TYPE A-T2: 4TH FLOOR

SVP A18

WM

65

18.03.16 27.06.14 22.11.13 01.11.13 23.08.13

Rev

Comment

By

Date

Stephen Davy Peter Smith Architects

250

250

210

SS A19 SVP

SW3

A02c SVP

392

DW

4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD

WM

SW3

B

Project Title

Privacy screen detail

W2 1032

250

FG

A09 SVP

CORE A

DW

262

FG

295

SVP A07

295

250 250

4844

P4

P6

PW LN CF GD WB

03 1310(AS)04-31

01 1310(AS)02-20

B

53

D05 CA-A4

100

nom. 864

P5

M&E 2598

Issued, As Built Dims added to privacy screens, ref updated Outlet references added Issued for construction Issued for comment

Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail: [email protected] Website: www.davysmitharchitects.co.uk

F/F

150

72

D C B A -

Client

200 592

D04 CA-A4

1410.5

D01 A9

SW1*

153 1050(s/o)

SW1

67 sqm 2B/3P

F-42 W04

231

SVP A04b

1578

200

231

2512

A17d

2326

Double

F-42 W03

Single

04 1310(AS)03-12

Copyright Stephen Davy Peter Smith Architects 2013

All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.

Drawing Title

Balcony / Terrace Setting Out Plans - BLOCK A

65

Ae 1994 Job No.

1310

Drawn By

Scale

TSo

1:50 @ A3

Date

Checked by

AUG 2013

GD

Drawing No.

1310(AS)04-41

Revision D