77.5 sqm 2B/4P

General Notes

1310(AS)04-31

Privacy screen detail

07 1310(AS)03-11

07 1310(AS)03-11

C

1B/2P

All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.

6092

725

240

3035

shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.

W6

1437

W2

1587

RWP

07 1310(AS)02-20 All drawings are indicative only. The sub-contractor is to submit

W05 F-11

W02 F-16

Terrace

Ca

65

Ca

1050

1650

W01 F-16

overflow

1500

W03 F-15

Outlet

RWP

65

Cb W02 F-15

overflow

C10

06 1310(AS)04-30 45.5 sqm

Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.

05 1310(AS)04-30

1B/2P

TYPICAL BALCONY TYPE C-B1: 2ND - 4TH FLOOR

Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.

C3

06 1310(AS)04-30

C2

All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.

slab edge slab edge

C9

Copyright Stephen Davy Peter Smith Architects 2013

All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.

W2

-

TYPICAL BALCONY TYPE C-B4: 2ND - 3RD FLOOR

1310(AS)03-11 08 Key

FG

345

08 1310(AS)03-11

M&E SW1

SVP C03

77

Cc

Ca Outlet

W01 F-14

W05 F-59

W2

Terrace 02 1310(AS)04-30

Terrace

Rev

Comment

PW LN CF TSo

18.03.16 27.06.14 22.11.13 12.09.13

WB 23.08.13

By

Date

overflow

3760

overflow

TYPICAL BALCONY TYPE C-B2: 2ND - 5TH FLOOR

Cb

1310(AS)04-31

1237.5

07 1310(AS)03-11

W2

1500

C3

Client

4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD Project Title

W2

W02 F-13

Drawing Title

Balcony / Terrace Setting Out Plans - BLOCK C

65

overflow

3188

slab edge

Job No.

C4 05 1310(AS)04-30

06 1310(AS)04-30

Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail: [email protected] Website: www.davysmitharchitects.co.uk

1650

W01 F-13

2904

08 1310(AS)03-11

BALCONY TYPE C-T2: 5TH FLOOR

215

65

W02 F-12 1050

Outlet

RWP

Ca

W6

slab edge

C2

Privacy screen detail

310(AS)02-20

Stephen Davy Peter Smith Architects

W6

-

310(AS)03-11 08

D Issued, As Built C Dims added to privacy screens, ref updated B Outlet references added A Overflows, privacy screen and handrails added, RC setting out revised - Issued for comment

3610

slab edge

C6

3112

2460

3262

1715

W6

115

AS BUILT

W2

Water butt

W03 F-13

RWP

W04 F-59

1310 06 1310(AS)04-30

TYPICAL BALCONY TYPE C-B3: 2ND - 5TH FLOOR

Drawn By

Scale

TSo

1:50 @ A3

Date

Checked by

AUG 2013

GD

Drawing No.

1310(AS)04-45

Revision D