1310(AS)03-
340
W2
D4 RWP
W03 F-17
Terrace
Outlet
1800
1650
W2
2650
2800
Terrace
C
Copyright Stephen Davy Peter Smith Architects 2013
5730
All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers. All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication. All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
W6
3283
General Notes All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.
W02 F-17
F-19 W04
1310(AS)03-11 08
D07 SVP
73.5 sqm 2B/4P
RWP
Outlet
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements. Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
slab edge overflow
D1
Db
Key
RWP
overflow
W6
slab edge
Dd 06 1310(AS)04-20
03 1310(AS)04-30
Outlet detail @ 2nd floor
Balcony detail @3rd+4th floor
05 1310(AS)04-30
02 1310(AS)04-21
05 1310(AS)04-30
Outlet detail @ 3rd+4th floor
Terrace detail @2nd floor
Balcony detail @3rd+4th floor
TERRACE TYPE D-T1 - 2ND FLOOR
AS BUILT
TYPICAL TERRACE TYPE D-T2 - 2ND-4TH FLOOR
340
D07 SVP
De
1310(AS)03-12 04
03 1310(AS)04-20
05 1310(AS)04-20
D3 01 1310(AS)04-31 F-38 W04
Privacy screen detail
65 1195.5
2650
Terrace
RWP Outlet
5817 65
RWP
1800
Terrace 1650
2883
W03 F-18
W02 F-18
3283 Outlet
W01 F-19
W02 F-19
W2
D1
PW LN CF TSo GD TSo WB
18.03.16 27.06.14 22.11.13 05.11.13 01.11.13 12.09.13 23.08.13
Rev
Comment
By
Date
overflow
De W6
Db Db Outlet detail @ 5th floor
05 1310(AS)04-30
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
slab edge
overflow
05 1310(AS)04-20
Stephen Davy Peter Smith Architects
Client
slab edge
06 1310(AS)04-20
Issued, As Built Dims added to privacy screens, ref updated References amended outlets details added Overflows to terrace DT1 amended Overflows, Detail refs and handrails added Issued for comment
D4 2800
Terrace
F E D C B A -
05 1310(AS)04-30
03 1310(AS)04-30
05 1310(AS)04-30
Balcony detail @3rd+4th floor
Balcony detail @3rd+4th floor
Balcony detail @3rd+4th floor
02 1310(AS)04-21
05 1310(AS)04-20
Terrace detail @2nd floor
Terrace detail @2nd floor
4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD Project Title
Outlet detail @ 3rd+4th floor
Drawing Title
TERRACE TYPE D-T1 - 3RD/4TH FLOOR
TYPICAL TERRACE TYPE D-T3 - 2ND-4TH FLOOR
Balcony / Terrace Setting Out Plans - BLOCK D Job No.
1310 Date
AUG 2013 Drawing No.
Drawn By
Scale
TSo
1:50 @ A3
Checked by
GD
1310(AS)04-47
Revision F