1310 (AS) 08/03 Door Schedule Block B AS BUILT Project No:.

Project Name:

1310 Union Road, Union Road / Clapham Road, Clapham, SW4 Client:

DURKAN

Door No

Location

Leaf Size

Frame Type

Fire rating

Vision Panel Ironmongery Type

Ventilation

Internal Internal Internal Internal Internal

FD 30S FD 30 FD 30 FD 30

No No No No No

U-A U-C U-D U-B U-B

10mm Undercut Note 5 10mm Undercut 10mm Undercut

Internal Internal Internal Internal Internal

FD 30S FD 30 FD 30 FD 30

No No No No No

U-A U-C U-B U-D U-B

10mm Undercut 10mm Undercut Note 5 10mm Undercut

Internal Internal Internal Internal Internal Internal

FD 30S FD 30 FD 30 FD 30 -

No No No No No No

U-A U-C U-B U-D U-B U-B

10mm Undercut 10mm Undercut Note 5 10mm Undercut 10mm Undercut

Internal Internal Internal Internal Internal

FD 30S FD 30 FD 30 FD 30

No No No No No

U-A U-D U-C U-B U-B

Note 5 10mm Undercut 10mm Undercut 10mm Undercut

Internal Internal Internal Internal Internal Internal Internal Internal

FD 30S FD 30 FD 30 FD 30 FD 30 FD 30 -

No No No No No No No No

U-A U-B U-D U-B U-B U-B U-C U-B

10mm Undercut Note 5 10mm Undercut 10mm Undercut 10mm Undercut 10mm Undercut 10mm Undercut

Internal Internal Internal Internal Internal

FD 30S FD 30 FD 30 FD 30

No No No No No

U-A U-D U-C U-B U-B

Note 5 10mm Undercut 10mm Undercut 10mm Undercut

Other Requirements

UNIT TYPE B - 1 (4no. Units: F-07, F-26, F-43, F-56) B-1 / D01 B-1 / D02 B-1 / D03 B-1 / D04 B-1 / D05

Entrance Bathroom Store/M&E Cupboard Kitchen/Living/Dining Bedroom

926 x 2040 x 44 838 x 1981 x 44 762 x 1981 x 44 838 x 1981 x 44 838 x 1981 x 44

UNIT TYPE B - 2 (3no. Units: F-10, F-29, F-46) B-2 / D01 B-2 / D02 B-2 / D03 B-2 / D04 B-2 / D05

Entrance 926 x 2040 x 44 Bathroom 838 x 1981 x 44 Bedroom 838 x 1981 x 44 Store/M&E Cupboard 2 / 533 x 1981 x 44 Kitchen/Living/Dining 838 x 1981 x 44

UNIT TYPE B - 3 (3no. Units: F-09, F-28, F-45) B-3 / D01 B-3 / D02 B-3 / D03 B-3 / D04 B-3 / D05 B-3 / D06

Entrance Bathroom Kitchen/Living/Dining M&E Cupboard Bedroom Wardrobe

926 x 2040 x 44 838 x 1981 x 44 838 x 1981 x 44 762 x 1981 x 44 838 x 1981 x 44 762 x 1981 x 44

UNIT TYPE B - 4 (3no. Units: F-08, F-27, F-44) B-4 / D01 B-4 / D02 B-4 / D03 B-4 / D04 B-4 / D05

Entrance 926 x 2040 x 44 M&E Cupboard 2 / 533 x 1981 x 44 Bathroom 838 x 1981 x 44 Kitchen/Living/Dining 838 x 1981 x 44 Bedroom 838 x 1981 x 44

UNIT TYPE B - 5 (1no. Units: F-58) B-5 / D01 B-5 / D02 B-5 / D03 B-5 / D04 B-5 / D05 B-5 / D06 B-5 / D07 B-3 / D08

Entrance 926 x 2044 x 44 Store 762 x 1981 x 44 M&E Cupboard 762 x 1981 x 44 Bedroom 1 838 x 1981 x 44 Bedroom 2 838 x 1981 x 44 Kitchen/Living/Dining 838 x 1981 x 44 Bathroom 838 x 1981 x 44 Wardrobe 2 / 533 x 1981 x 44

UNIT TYPE B - 6 (1no. Units: F-57) B-6 / D01 B-6 / D02 B-6 / D03 B-6 / D04 B-6 / D05

Entrance 926 x 2040 x 44 Store/M&E Cupboard 2 / 533 x 1981 x 44 Bathroom 838 x 1981 x 44 Kitchen/Living/Dining 838 x 1981 x 44 Bedroom 838 x 1981 x 44

NOTES 1. The contractor is to make allowance for planning and adjusting the bottom of doors to suit floor finish and any threshold strip. 2. This schedule is to be read in conjunction with all other SDPSA drawings 1310 (AS) 08/01 and GA plans. Refer to ER's for further specifications. 3. Frames to be fixed at maximum of 300mm centres. 4. Internal lining (FD30) spec- Minimum 32mm lining with minimum density of 510kg/m3. Stops to be minimum 12mm pinned and glued. 5. 150x150mm grilles provided at high and low level in store / airing cupboard doors containing gas meters or boilers. All to M & E requirements. 6. All external doors to have double glazed unit where noted. External pane to be laminated, internal pane to be toughened. 7. All fire doors with suffix 'S' to have intumescent strips and smoke seals. 8. Entrance doors to have a minimum mass per unit area of 25kg/m3 or a minimum sound reduction index of 29dBRw. 9. For entrance door elevations refer to door detail drawings 1310 (AS) 08/01. 10. Ensure transfer of air throughout the dwelling, provide 10mm undercut to all internal doors above floor finish. 11. This schedule is to be read in conjunction with ironmongery schedule 1310 (AS) 08/08 & 08/09. 12. Doors to be ply painted finish, flush with frames. In accordance with the ER's. 13. All shared ownership and private internal doors to be real wood veneer, flush with frames. In accordance with the ER's.

Fanshaw House, Fanshaw Street, London N1 6HX Tel 020 7739 2020 [email protected] www.davysmitharchitects.co.uk

REVISIONS - Issued for Tender A Issued for Construction B Ironmongery type added, ammendments shaded C Issued, As Built

19/08/13 20/09/13 26/03/14 20/05/15