5mm Nylon thermal break pad to isolate wall brackets from sheathing boards by rainscreen cladding manufacturer.
Proprietary perpend weep holes at max. 1000mm c/c. colour to match mortar Min. 2no per openings
Preformed drainage slots
Compriband 600 compressible sealant to fill gaps around window frame
Compriband 600 compressible sealant to fill gaps around window frame
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
EDPM to mechanically fixed to window frame prior to window installation and bonded to sheathing boards to manufacturers recommendation
Flexible sealant to fill gaps between dry lining and window frame
Flexible sealant to fill gaps between dry lining and window frame
Structural opening*
EDPM to mechanically fixed to window frame prior to window installation and bonded to lintel to manufacturers recommendation
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
25x50mm wrought softwood curtain batten (FSC or PEFC), fixed 150mm above window opening
TYPICAL HEAD DETAIL - RENDER
*As shown on drawings 1310(AS)03/01-1310(AS)03/05.
50mm
25x50mm wrought softwood curtain batten (FSC or PEFC), fixed 150mm above window opening
TYPICAL HEAD DETAIL - CLADDING
*As shown on drawings 1310(AS)03/01-1310(AS)03/05.
25x50mm wrought softwood curtain batten (FSC or PEFC), fixed 150mm above window opening
TYPICAL HEAD DETAIL - BRICKWORK
*As shown on drawings 1310(AS)03/01-1310(AS)03/05.
25mm moisture resistant non-formaldehyde MDF cill board on timber packers, edge profile: rounded nosing.
25mm moisture resistant non-formaldehyde MDF cill board on timber packers, edge profile: rounded nosing.
25mm moisture resistant non-formaldehyde MDF cill board on timber packers, edge profile: rounded nosing.
Compriband 600 compressible sealant to fill gaps around window frame
Compriband 600 compressible sealant to fill gaps around window frame
Compriband 600 compressible sealant to fill gaps around window frame
PPC aluminium cill profile with drip detail, colour: RAL 7015 Matt (Slate Grey)
PPC aluminium cill profile with drip detail, colour: RAL 7015 Matt (Slate Grey)
EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
All cavity closers to be a Kingspan Thermabate, size to suit individual cavity.
AS BUILT Legend
B
ion
EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation
35mm
BBA approved breather membrane lapped into window opening
BBA approved breather membrane lapped into window opening
Flexible sealant to fill gaps between dry lining and window frame
Flexible sealant to fill gaps between dry lining and window frame
Flexible sealant to fill gaps between dry lining and window frame
TYPICAL CILL DETAIL - CLADDING
Structural opening*
TYPICAL CILL DETAIL - BRICKWORK
Additional stud and brick-tie-channel to adjacent opening as SFS installer's details
Structural opening*
C B A
Issued, As Built EDPM and cavity closers added as clouded. Issued for construction.
PW 18.03.16 TSo 09.12.13 TSo 23.08.13
-
First Issue
TSo 24.07.13
5mm Nylon thermal break pad to isolate wall brackets from sheathing boards by rainscreen cladding manufacturer.
Compriband 600 compressible sealant to fill gaps around window frame EDPM dressed to window pod to manufacturers details
4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD
Compriband 600 compressible sealant to fill gaps around window frame Arbosil silicone seal to aluminium cill, sealant colour: Grey
Project
50mm
EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation
Client
Union Road Union Road / Clapham Road Clapham SW4 Drawing Title
102.5mm thk stretcher bond facing brick wall with bucket handle joints Job No.
Drawn By
Scale
1310
TSo
1:5 @ A1
Date
Checked By
July 2013
TSo/KK
Drawing No.
TYPICAL JAMB DETAIL - RENDER
TYPICAL JAMB DETAIL - CLADDING
Date
35mm
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
Flexible sealant to fill gaps between dry lining and window frame Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
50mm
EDPM to mechanically fixed to window frame prior to window installation and bonded to sheathing boards to manufacturers recommendation
10mm
10mm
10mm 35mm
Arbosil silicone seal to aluminium cill, sealant colour: Grey
Through colour render system applied to blockwork, colour: White, installed in accordance with manufacturer's details and by approved contractor.
Flexible sealant to fill gaps between dry lining and window frame
35mm
Compriband 600 compressible sealant to fill gaps around window frame
50mm
EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation
By
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
Comment
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
BBA approved breather membrane lapped into window opening
Flexible sealant to fill gaps between dry lining and window frame
N
stephen davy architects peter smith
Structural opening*
BBA approved breather membrane lapped into window opening
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
ad
Key
Rev
Brass rainscreen cladding TBC by Durkan, helping hand brackets fixed to stud through sheathing board, fixing centres refer to manufacturer recommendation.
Ro
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
BBA approved breather membrane lapped into window opening
Additional stud and brick-tie-channel to adjacent opening as SFS installer's details
D
35mm
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
5mm Nylon thermal break pad to isolate wall brackets from sheathing boards by rainscreen cladding manufacturer.
C
A Un
EDPM dressed to window pod to manufacturers details
TYPICAL CILL DETAIL - RENDER
Refer to drawings 1310(AS)07/-- and
*As shown 1310(AS)07/-on drawings 1310(AS)03/01 - 03/05
PPC aluminium cill profile with drip detail, colour: RAL 7015 Matt (Slate Grey)
EDPM to mechanically fixed to window frame prior to window installation and bonded to sheathing boards to manufacturers recommendation
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
Refer to drawing 1310(AS)07/--
Flexible sealant to fill gaps between dry lining and window frame
Velfac PPC aluminium composite timber system, profile shown indicatively, frame colour: RAL 7015 Matt (Slate Grey)
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
Refer to drawing series 1310(AS)04/01
Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs
Velfac PPC aluminium composite timber system, profile shown indicatively, frame colour: RAL 7015 Matt (Slate Grey)
35mm
Refer to drawing series 1310(AS)02/01
EDPM to mechanically fixed to window frame prior to window installation and bonded to lintel to manufacturers recommendation
Velfac PPC aluminium composite timber system, profile shown indicatively, frame colour: RAL 7015 Matt (Slate Grey)
Render stop beads to manufacturer's details, render finish to window reveal
Specific Notes
50mm
Brickwork to window reveal
Structural opening*
Compriband 600 compressible sealant to fill gaps around window frame
Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
ad
50mm
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.
Ro
Render angle beads and stop beads to manufacturer's details, render finish to window reveal
This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
Proprietary perpend weep holes at max. 1000mm c/c. colour to match mortar Min. 2no per openings
All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work.
IG Lintel support to masonry skin, specification to SE / manufacturers dwgs
EDPM dressed down to window pod to manufacturers details
Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.
10mm
m
IG Lintel support to masonry skin, specification to SE / manufacturers dwgs
All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.
ha
10mm
All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.
BBA approved DPC cavity tray fixed to insulation using fixing pins through fixing strip and jointing tape in accordance with manufacturer's requirements. System suitable for use with light gauge steel frame. Cavity tray to have pre-formed cloaks.
10mm
Copyright Stephen Davy Peter Smith Architects 2013
All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.
102.5mm thk stretcher bond facing brick wall with bucket handle joints
Brass rainscreen cladding, TBC by Durkan
BBA approved DPC cavity tray fixed to insulation using fixing pins through fixing strip and jointing tape in accordance with manufacturer's requirements. System suitable for use with light gauge steel frame. Cavity tray to have pre-formed cloaks.
C
Cl ap
Through colour render system applied to blockwork, colour: White, installed in accordance with manufacturer's details and by approved contractor.
General Notes
BBA approved breather membrane lapped over DPC cavity tray
BBA approved breather membrane
Structural opening*
BBA approved breather membrane lapped over DPC cavity tray
TYPICAL JAMB DETAIL - BRICKWORK
1310(AS)03/11
Revision
C