PDF Format


[PDF]PDF Format - Rackcdn.comc24110ab053e5c234c6f-9b7150e100ab604df0aafbaf58c9fe02.r58.cf3.rackcdn.com/...

0 downloads 116 Views 380KB Size

5mm Nylon thermal break pad to isolate wall brackets from sheathing boards by rainscreen cladding manufacturer.

Proprietary perpend weep holes at max. 1000mm c/c. colour to match mortar Min. 2no per openings

Preformed drainage slots

Compriband 600 compressible sealant to fill gaps around window frame

Compriband 600 compressible sealant to fill gaps around window frame

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

EDPM to mechanically fixed to window frame prior to window installation and bonded to sheathing boards to manufacturers recommendation

Flexible sealant to fill gaps between dry lining and window frame

Flexible sealant to fill gaps between dry lining and window frame

Structural opening*

EDPM to mechanically fixed to window frame prior to window installation and bonded to lintel to manufacturers recommendation

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

25x50mm wrought softwood curtain batten (FSC or PEFC), fixed 150mm above window opening

TYPICAL HEAD DETAIL - RENDER

*As shown on drawings 1310(AS)03/01-1310(AS)03/05.

50mm

25x50mm wrought softwood curtain batten (FSC or PEFC), fixed 150mm above window opening

TYPICAL HEAD DETAIL - CLADDING

*As shown on drawings 1310(AS)03/01-1310(AS)03/05.

25x50mm wrought softwood curtain batten (FSC or PEFC), fixed 150mm above window opening

TYPICAL HEAD DETAIL - BRICKWORK

*As shown on drawings 1310(AS)03/01-1310(AS)03/05.

25mm moisture resistant non-formaldehyde MDF cill board on timber packers, edge profile: rounded nosing.

25mm moisture resistant non-formaldehyde MDF cill board on timber packers, edge profile: rounded nosing.

25mm moisture resistant non-formaldehyde MDF cill board on timber packers, edge profile: rounded nosing.

Compriband 600 compressible sealant to fill gaps around window frame

Compriband 600 compressible sealant to fill gaps around window frame

Compriband 600 compressible sealant to fill gaps around window frame

PPC aluminium cill profile with drip detail, colour: RAL 7015 Matt (Slate Grey)

PPC aluminium cill profile with drip detail, colour: RAL 7015 Matt (Slate Grey)

EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

All cavity closers to be a Kingspan Thermabate, size to suit individual cavity.

AS BUILT Legend

B

ion

EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation

35mm

BBA approved breather membrane lapped into window opening

BBA approved breather membrane lapped into window opening

Flexible sealant to fill gaps between dry lining and window frame

Flexible sealant to fill gaps between dry lining and window frame

Flexible sealant to fill gaps between dry lining and window frame

TYPICAL CILL DETAIL - CLADDING

Structural opening*

TYPICAL CILL DETAIL - BRICKWORK

Additional stud and brick-tie-channel to adjacent opening as SFS installer's details

Structural opening*

C B A

Issued, As Built EDPM and cavity closers added as clouded. Issued for construction.

PW 18.03.16 TSo 09.12.13 TSo 23.08.13

-

First Issue

TSo 24.07.13

5mm Nylon thermal break pad to isolate wall brackets from sheathing boards by rainscreen cladding manufacturer.

Compriband 600 compressible sealant to fill gaps around window frame EDPM dressed to window pod to manufacturers details

4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD

Compriband 600 compressible sealant to fill gaps around window frame Arbosil silicone seal to aluminium cill, sealant colour: Grey

Project

50mm

EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation

Client

Union Road Union Road / Clapham Road Clapham SW4 Drawing Title

102.5mm thk stretcher bond facing brick wall with bucket handle joints Job No.

Drawn By

Scale

1310

TSo

1:5 @ A1

Date

Checked By

July 2013

TSo/KK

Drawing No.

TYPICAL JAMB DETAIL - RENDER

TYPICAL JAMB DETAIL - CLADDING

Date

35mm

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

Flexible sealant to fill gaps between dry lining and window frame Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

50mm

EDPM to mechanically fixed to window frame prior to window installation and bonded to sheathing boards to manufacturers recommendation

10mm

10mm

10mm 35mm

Arbosil silicone seal to aluminium cill, sealant colour: Grey

Through colour render system applied to blockwork, colour: White, installed in accordance with manufacturer's details and by approved contractor.

Flexible sealant to fill gaps between dry lining and window frame

35mm

Compriband 600 compressible sealant to fill gaps around window frame

50mm

EDPM to mechanically fixed to window frame prior to window installation and bonded to masonry to manufacturers recommendation

By

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

Comment

Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail: [email protected] Website: www.davysmitharchitects.co.uk

BBA approved breather membrane lapped into window opening

Flexible sealant to fill gaps between dry lining and window frame

N

stephen davy architects peter smith

Structural opening*

BBA approved breather membrane lapped into window opening

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

ad

Key

Rev

Brass rainscreen cladding TBC by Durkan, helping hand brackets fixed to stud through sheathing board, fixing centres refer to manufacturer recommendation.

Ro

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

BBA approved breather membrane lapped into window opening

Additional stud and brick-tie-channel to adjacent opening as SFS installer's details

D

35mm

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

5mm Nylon thermal break pad to isolate wall brackets from sheathing boards by rainscreen cladding manufacturer.

C

A Un

EDPM dressed to window pod to manufacturers details

TYPICAL CILL DETAIL - RENDER

Refer to drawings 1310(AS)07/-- and

*As shown 1310(AS)07/-on drawings 1310(AS)03/01 - 03/05

PPC aluminium cill profile with drip detail, colour: RAL 7015 Matt (Slate Grey)

EDPM to mechanically fixed to window frame prior to window installation and bonded to sheathing boards to manufacturers recommendation

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

Refer to drawing 1310(AS)07/--

Flexible sealant to fill gaps between dry lining and window frame

Velfac PPC aluminium composite timber system, profile shown indicatively, frame colour: RAL 7015 Matt (Slate Grey)

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

Refer to drawing series 1310(AS)04/01

Window packer and fixing lugs to metsec frame as window manufacturer's details, PU expanding foam/ mineral wool insulation to fill gaps between fixing lugs

Velfac PPC aluminium composite timber system, profile shown indicatively, frame colour: RAL 7015 Matt (Slate Grey)

35mm

Refer to drawing series 1310(AS)02/01

EDPM to mechanically fixed to window frame prior to window installation and bonded to lintel to manufacturers recommendation

Velfac PPC aluminium composite timber system, profile shown indicatively, frame colour: RAL 7015 Matt (Slate Grey)

Render stop beads to manufacturer's details, render finish to window reveal

Specific Notes

50mm

Brickwork to window reveal

Structural opening*

Compriband 600 compressible sealant to fill gaps around window frame

Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.

ad

50mm

Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.

Ro

Render angle beads and stop beads to manufacturer's details, render finish to window reveal

This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

Proprietary perpend weep holes at max. 1000mm c/c. colour to match mortar Min. 2no per openings

All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work.

IG Lintel support to masonry skin, specification to SE / manufacturers dwgs

EDPM dressed down to window pod to manufacturers details

Insulated cavity closer to fill cavity width, to provide thermal resistance of not less than 0.45m2K/W and to form integral DPC.

10mm

m

IG Lintel support to masonry skin, specification to SE / manufacturers dwgs

All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.

ha

10mm

All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.

BBA approved DPC cavity tray fixed to insulation using fixing pins through fixing strip and jointing tape in accordance with manufacturer's requirements. System suitable for use with light gauge steel frame. Cavity tray to have pre-formed cloaks.

10mm

Copyright Stephen Davy Peter Smith Architects 2013

All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.

102.5mm thk stretcher bond facing brick wall with bucket handle joints

Brass rainscreen cladding, TBC by Durkan

BBA approved DPC cavity tray fixed to insulation using fixing pins through fixing strip and jointing tape in accordance with manufacturer's requirements. System suitable for use with light gauge steel frame. Cavity tray to have pre-formed cloaks.

C

Cl ap

Through colour render system applied to blockwork, colour: White, installed in accordance with manufacturer's details and by approved contractor.

General Notes

BBA approved breather membrane lapped over DPC cavity tray

BBA approved breather membrane

Structural opening*

BBA approved breather membrane lapped over DPC cavity tray

TYPICAL JAMB DETAIL - BRICKWORK

1310(AS)03/11

Revision

C