INTERIOR - FLAT X / COMMUNAL AREA
RESIDENTIAL
INTERIOR - FLAT Y / COMMUNAL AREA
RESIDENIAL General Notes
Skirting to ER's
SW1, SW2, SW3, SW8
C
SW4
Flexible or acoustic sealant between wall lining and floor Concrete column to SE details
Perimeter insulation, isolating screed from metal frame.
F4
RESIDENTIAL
RESIDENTIAL
Skirting to ER's
DPC laid between floor surface and metal stud channels, lapped up to face of studwork prior to installation of perimeter insulation
SW1, SW2, SW3, SW8 F6
FFL (Screed)
Skirting to ER's
10mm Cellecta Yelofon ES10 Perimeter flanking strip or equal to all ends and edges, ensure that no contact is made between floor construction and skirting and dry lining boards. GWP <5
FFL (Screed)
Flexible or acoustic sealant between wall lining and floor 10mm Cellecta Yelofon ES10 Perimeter flanking strip or equal to all ends and edges, ensure that no contact is made between floor construction and skirting and dry lining boards. GWP <5. Installed to manufacturer's requirements.
F6 FFL (Screed)
SSL Isolating membrane / vapour control barrier, to be laid over insulation. Membrane must be adequately lapped and sealed before laying screed. The surface should be smooth to avoid cracking of screed.
SSL
SSL
Copyright Stephen Davy Peter Smith Architects 2013
All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work. All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers. All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication. All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
DPC laid between floor surface and metal stud channels Continuous Gyproc FireStrip to U/S of slab to provide 60min fire resistance. Fixing through firestop into structure at 600mm max. centres.
Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
Steel angle trim with sealant fixed to the structural soffit either side of partition as shown to maintain acoustic performance
Specific Notes Please also refer to the architect's fire strategy drawings for the required fire ratings.
15
PFC Corofil C500 firestop or equal to fit under compression between top of masonry wall and U/S of concrete slab to meet required fire rating Fire rating requirements: 60mins.
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.
Linings cut short to allow for deflection. Gyproc Coreboard or equal to create dropped soffit for deflection head
Seal all perimeter joints with Gyproc jointing materials or caulk with Gyproc sealant
SW4 INTERIOR COMMERCIAL UNIT X
Seal all perimeter joints with Gyproc jointing materials or caulk with Gyproc sealant
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
INTERIOR COMMERCIAL UNIT Y
TYPICAL HEAD AND BASE DETAIL - GROUND FLOOR / FIRST FLOOR
Encasement
TYPICAL HEAD AND BASE DETAIL - SEPARATING WALL / SEPARATING FLOOR
TYPICAL BASE DETAIL - CONCRETE COLUMN
Seperating Wall
INTERIOR - RESIDENTIAL UNIT X
Internal partition (build up varies)
50mm metal or SW timber framing Pipe boxed in with two layers gypsum- based board, each layer nom. 8kg/m2. Moisture resistant plasterboard to kitchens/bathrooms/W.C's.
SW1, SW2, SW3, SW8
Skirting to ER's, screwed to plasterboard and metal studs.
25mm (min) mineral wool quilt (min. 10kg/m3) around pipes (full height).
Skirting to E.R.'s
F6
FFL (Screed)
FFL Screed
Cut linings short to allow for deflection, fill gap with acoustic flexible sealant.
SSL
F6
Base channel screwed to screed.
1310 F6
Seal any gaps at the base of linings to both sides with Gyproc Sealant (in conjunction with Gyproc Joint Filler) in accordance with the manufacturer's requirements. Firestop at the head using Gyproc Plank with continuous line of Gyproc FireStrip. Gypframe Deep Flange Floor & Ceiling Channel is fixed through firestop to soffit at 600mm centres using suitable fixings. No fixings should be made through the boards into the flanges of the head channel.
SSL
Continuous bead of Gyproc (or similar approved) sealant
min. 10mm depth of Hilti CP 601s silicone sealant to provide watertight seal to manufacturers details
Concrete slab to S.E.
Hilti CP680 intumescent cast-in firestop device, gaps to be packed with min 100mm depth 60kg/m3 mineral wool. Minimum fire resistance: Blocks B & C: 60minutes. Block A: 90 minutes.
250
SVP
Legend
Optional to increase acoustic performance: Gypframe GA2 Steel Angle and sealant to manufacturer's recommendations.
AS BUILT
To ensure acoustic performance: Gypframe GA2 Steel Angle and sealant to manufacturer's recommendations.
Key Cut studs 15mm short to allow for the deflection
Seal all perimeter joints with Gyproc jointing materials or caulk with Gyproc sealant
Internal partition (build up varies) Separating wall (where applicable)
INTERIOR - RESIDENTIAL UNIT Y
TYPICAL SVP ENCASEMENT SECTION DETAIL
TYPICAL HEAD AND BASE DETAILS - INTERNAL PARTITION
ALTERNATIVE HEAD DETAILS - INTERNAL PARTITION B A -
Issued, As Built Issued for Construction Issued for Comment
Rev
RESIDENTIAL
PW 18.03.16 GD 12/09/13 WB 15/08/13
Comment
By
Date
RESIDENIAL
SW1, SW2, SW3, SW8
stephen davy architects peter smith
Skirting to ER's Flexible or acoustic sealant between wall lining and floor 10mm Cellecta Yelofon ES10 Perimeter flanking strip or equal to all ends and edges, ensure that no contact is made between floor construction and skirting and dry lining boards. GWP <5
F6 FFL (Screed)
SSL
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
Client
DPC laid between floor surface and metal stud channels
Durkan House 214-224 High Street Waltham Cross Hertfordshire EN8 7DU Project
Union Road Union Road / Clapham Road Clapham SW4 PFC Corofil C500 firestop or equal to fit under compression between top of masonary wall and U/S of concrete slab to meet required fire rating. Fire rating requirements: 60mins
SW10 RESIDENTIAL
RESIDENTIAL
Drawing Title
Typical Partition Details - Section
Job No.
Drawn By
Scale
1310
WB
1:5 @ A1
Date
Checked By
Aug 2013 Drawing No.
TYPICAL HEAD AND BASE DETAIL - SEPARATING WALL / SEPARATING FLOOR
1310 (AS) 07/05
Revision
B