NOTES PLEASE READ THIS DRAWING WITH THE FOLLOWING DRAWINGS: MECHANICAL SERVICES DETAILS & NOTES - DET17/051/01 TYPICAL DWELLING HEATING & DOMESTIC SERVICES DISTRIBUTION SCHEMATIC - SC17/051/01

F-04

THE LATEST KITCHEN MANUFACTURERS DRAWINGS & ARCHITECTS BATHROOM DRAWINGS.

F-04 L0 41.29 SQ. M L0 444.42 Sq. '

L0 41.29 SQ. M L0 444.42 Sq. '

Store

bathroom

LIFETIME HOMES SPECIFICATION ALL CONTROLS INCLUDING AECV, SC & THERMOSTATS TO BE BETWEEN 450mm-1200mm AFFL & AT LEAST 300mm AWAY FROM ANY INTERNAL CORNER.

Store Ø22 HWS drop F/A to L/L and Ø22 MWS (Unbalanced) rises T/A from L/L. Ø22 MWS (Balanced) drops F/A from L/L. Ø22 HWS and MWS (Balanced) branch at L/L with connections to bath (with TMV), WHB and WC.

Cond

Store Wardrobe

Ø22 HWS drop T/B from L/L Ø22 MWS (Unbalanced) rises F/B to L/L.

bathroom Ø125 extract duct rises T/A c/w fire collar below.

Cond

Ø125 extract duct rises F/B c/w fire collar below.

FS Ø125 supply duct drops F/A c/w fire collar below.

Store FS

Wardrobe FS

Ø125 supply duct drops T/B c/w fire collar below.

FS

204x60 duct at H/L (typical)

Bedroom 2

Bedroom 2

Minimum distance between wall & grille to be 200mm (Typical)

Water Services Layout

R6

Ventilation Services Layout

F-04

F-04

L0 41.29 SQ. M L0 444.42 Sq. '

Ø22 HTG F&R drops T/B for lower ground radiator connections. Each pair of F&R pipework passes through a single Ø50 builders work hole - please refer to Drg - FT17/051/F04/BW HTG F&R manifolds at H/L. Ø22 HTG F&R drop F/A connects to manifolds.

L0 41.29 SQ. M L0 444.42 Sq. '

Towel rail connections rise T/A. Radiator connections drop to L/L.

R7

Store

bathroom

RE

Store

Cond

bathroom

AS BUILT

RE

Cond

Store

Store Wardrobe

Wardrobe

R5

Bedroom 2

RE

Existing Ø110 SVP with Ø110 WC waste connection, Ø32 WHB and Ø40 bath.

Radiator connections drop to L/L (typical).

Bedroom 2

Radiator connections rise T/A.

SERVICEPLAN Heating Services Layout

Drainage Services Layout

THIS DRAWING IS BASED ON THE FOLLOWING:CONSULTANTS DRG K170123-M(B)110Rev C2 ARCHITECTS DRG 1901/C/B100 Rev C2