[PDF]PDF Format - Rackcdn.comc24110ab053e5c234c6f-9b7150e100ab604df0aafbaf58c9fe02.r58.cf3.rackcdn.com/...
0 downloads
126 Views
446KB Size
NOTES PLEASE READ THIS DRAWING WITH THE FOLLOWING DRAWINGS: MECHANICAL SERVICES DETAILS & NOTES - DET17/051/01 TYPICAL DWELLING HEATING & DOMESTIC SERVICES DISTRIBUTION SCHEMATIC - SC17/051/01
F-04
THE LATEST KITCHEN MANUFACTURERS DRAWINGS & ARCHITECTS BATHROOM DRAWINGS.
F-04 L0 41.29 SQ. M L0 444.42 Sq. '
L0 41.29 SQ. M L0 444.42 Sq. '
Store
bathroom
LIFETIME HOMES SPECIFICATION ALL CONTROLS INCLUDING AECV, SC & THERMOSTATS TO BE BETWEEN 450mm-1200mm AFFL & AT LEAST 300mm AWAY FROM ANY INTERNAL CORNER.
Store Ø22 HWS drop F/A to L/L and Ø22 MWS (Unbalanced) rises T/A from L/L. Ø22 MWS (Balanced) drops F/A from L/L. Ø22 HWS and MWS (Balanced) branch at L/L with connections to bath (with TMV), WHB and WC.
Cond
Store Wardrobe
Ø22 HWS drop T/B from L/L Ø22 MWS (Unbalanced) rises F/B to L/L.
bathroom Ø125 extract duct rises T/A c/w fire collar below.
Cond
Ø125 extract duct rises F/B c/w fire collar below.
FS Ø125 supply duct drops F/A c/w fire collar below.
Store FS
Wardrobe FS
Ø125 supply duct drops T/B c/w fire collar below.
FS
204x60 duct at H/L (typical)
Bedroom 2
Bedroom 2
Minimum distance between wall & grille to be 200mm (Typical)
Water Services Layout
R6
Ventilation Services Layout
F-04
F-04
L0 41.29 SQ. M L0 444.42 Sq. '
Ø22 HTG F&R drops T/B for lower ground radiator connections. Each pair of F&R pipework passes through a single Ø50 builders work hole - please refer to Drg - FT17/051/F04/BW HTG F&R manifolds at H/L. Ø22 HTG F&R drop F/A connects to manifolds.
L0 41.29 SQ. M L0 444.42 Sq. '
Towel rail connections rise T/A. Radiator connections drop to L/L.
R7
Store
bathroom
RE
Store
Cond
bathroom
AS BUILT
RE
Cond
Store
Store Wardrobe
Wardrobe
R5
Bedroom 2
RE
Existing Ø110 SVP with Ø110 WC waste connection, Ø32 WHB and Ø40 bath.
Radiator connections drop to L/L (typical).
Bedroom 2
Radiator connections rise T/A.
SERVICEPLAN Heating Services Layout
Drainage Services Layout
THIS DRAWING IS BASED ON THE FOLLOWING:CONSULTANTS DRG K170123-M(B)110Rev C2 ARCHITECTS DRG 1901/C/B100 Rev C2