PDF Format


[PDF]PDF Format - Rackcdn.comc24110ab053e5c234c6f-9b7150e100ab604df0aafbaf58c9fe02.r58.cf3.rackcdn.com/...

0 downloads 120 Views 200KB Size

Revisions No. Revision note

Date

By

Check

C1

CONSTRUCTION ISSUE

13.04.17

MD

PC

C2

FINAL CONSTRUCTION ISSUE

27.10.17

MD

PC

NOTES WITH REFERENCE TO APPROVED DOCUMENT B VOL1 & VOL2 & BWC FIRE STRATEGY REPORT

Flats to be fitted LD1 Fire Alarms

Smoke and heat detectors system should be fitted to the following: BS 5839-6:2004 BS 5446-2:2003

KEY

SVP

60 min fire resisting compartmentation SVP

IW07

sump access corridor

30 min fire resisting

Home office location 1800x600

compartmentation Travel distance from furthest point

IW07

within dwelling from unit front door or MOE IW06

IW02 B-D-LG02

B-D-LG03

store

Study

Communal protected stair

IW06

IW01 B-D-LG01

IW07

Utility

IW02

FD30

IW02

IW01

Sump

WM

Dry riser

WM

WC

Sump

IW03 SVP

IW02

AOV- Automatic opening vent linked

FD30

SVP

to a detector i the stairway at each

FD30

B-D-LG04

level

B-D-LG11 SVP

FD30

SVP

IW07

SVP

IW02

SVP

Sprinkler system subject to detailed sub-contractor proposals

B-D-LG08

F-C = 2600

IW07

9.8m

DH - Dwelling house with separate external

store

FD30

IW07

IW01

FD30

BDLG06

L-139.06 SQ. M L-1420.44 Sq. '

BDLG05

F-03

IW07

IW01

store

entrance

WM

store WM

SD B-D-LG12

IW01

FD30 B-D-LG09

B-D-LG10

IW07

IW07

FD30

Door details to be read in conjunction with door schedule FD30s - 30 minute Fire resistance door with smoke seal

IW07 IW07

FD20 - 20 minute fire resistance door

SVP

IW07

Cond

KLS - Keep Locked Shut IW07

IW02

SC - Self Closing

6.7m

VP - Vision Panel NFR - Not Fire Rated

F-06

BH = 2400

L-146.88 SQ. M L-1504.60 Sq. ' F-C = 2600

Living 10.6m BH = 2400

10.6m

IW07

F-05

F-04 L-148.72 SQ. M L-1524.38 Sq. ' F-C = 2600

Kitchen/Dining/Living

IW07

IW07

F-C = 2600

Kitchen/Dining/Living

Key Plan

B

oa d

D

R

IW07

C

A

l ap ha m

IW07

Un i on Ro ad

N

C

IW07

IW07

L-144.81 SQ. M L-1482.32 Sq. '

Li ght wel l

Dining

DOORS

B-D-LG13

B-D-LG07

Smoke detector. Others indicated on M+E drawings.

FD30

Cond

Kitchen

EW - Emergency egress window or door

IW01 IW01

SVP

sum p access cor r i dor

FD30

Client

Biscoe+ Stanton ARCHITECTS

0

5 St. John's Place London EC1M 4NP Tel:020 7490 7919 Fax:020 7490 7929 e mail: mail a biscoestanton.co.uk

5M

Project

Drawing Status

CONSTRUCTION

SINGER MEWS, LONDON SW4

Date:

11.04.17

Drawn by:

MD

Checked:

PC

1:50 @ A1 Scale

1:100 @ A3 Revision

Title

Drawing No:

BLOCK B FIRE STRATEGY LOWER GROUND FLOOR PLAN

1901/C/B400 C2 c

Biscoe + Stanton Architects

ISO form outer border only visible when printed using Oversize ISO forms. -Reduced size prints do not have outer border