PDF Format


[PDF]PDF Format - Rackcdn.comc24110ab053e5c234c6f-9b7150e100ab604df0aafbaf58c9fe02.r58.cf3.rackcdn.com/...

0 downloads 118 Views 334KB Size

A1 SHEET

LEGEND

VANDAL RESISTANT INTERCOM UNIT VIDEO VIA SEPARATE COLOUR MINI-DOME CAMERA

AUDIO /VISUAL VANDAL RESISTANT INTERCOM UNIT (SINGLE FOR LIVE/WORK UNITS)

CONTROL BOX

INTERCOM/ACCESS CONTROL MASTER CONTROL BOX

PROXIMITY READER DEVICE

EXIT BUTTON

RESETABLE EXIT BREAK GLASS

DOOR LOCKING DEVICE (MAGLOCK/ELECTONIC KEEP) FIREMAN'S EMERGENCY DROP SWITCH

CCTV COLOUR MINI DOME CAMERA NOTE: LIVE/WORK UNITS LW-01 & LW-02 SHALL HAVE THEIR OWN INDIVIDUAL DOOR ENTRY PANEL. ACCESS SHALL NOT BE POSSIBLE VIA THE BLOCK A COMMUNAL ENTRANCE PANEL STAND ALONE ENTRANCE PANEL FOR LW-01

NOTE: LIVE/WORK UNITS LW-03, LW-04 & LW-06 SHALL HAVE THEIR OWN INDIVIDUAL DOOR ENTRY PANEL AND WILL BE ACCESSIBLE VIA THE MAIN BLOCK B DOOR ENTRY PANEL FOR ACCESS VIA THE COMMUNAL ENTRANCE

DOOR ENTRANCE PANEL FOR LW-05

STAND ALONE ENTRANCE PANEL FOR LW-02

NOTE: LIVE/WORK UNIT -LW-11 SHALL HAVE ITS OWN INDIVIDUAL DOOR ENTRY PANEL AND WILL BE ACCESSIBLE VIA THE MAIN BLOCK C DOOR ENTRY PANELS FOR ACCESS VIA THE COMMUNAL ENTRANCE

NOTE: LIVE/WORK UNIT LW-12 SHALL HAVE IT'S OWN INDIVIDUAL DOOR ENTRY PANEL. ACCESS SHALL NOT BE POSSIBLE VIA THE BLOCK D COMMUNAL ENTRANCE PANEL

AUDIO/VISUAL DWELLING HANDSET

DOOR ENTRANCE PANEL FOR LW-12

JB

FLOOR CONTROLLER

DUCTED SUPPLY FROM BLOCK A TO LW01 DOOR ENTRANCE PANEL FOR LW-03 FAIL SAFE FIRE ALARM INTERFACE

DOOR ENTRANCE PANEL FOR LW-06

DOOR ENTRANCE PANEL FOR LW-11

FAIL SAFE FIRE ALARM INTERFACE

BLOCK ACCESS CONTROL PANEL

MAIN ACCESS CONTROL PANEL

GATES ACCESS CONTROL PANEL

Block A Entrance CCTV Camera

BLOCK ACCESS CONTROL PANEL

BLOCK ACCESS CONTROL PANEL

Block B Entrance CCTV Camera

Main Entrance Pedestrian CCTV Camera Block A Main Entrance

FAIL SAFE FIRE ALARM INTERFACE

Main Entrance Pedestrian Gates

FAIL SAFE FIRE ALARM INTERFACE

BLOCK ACCESS CONTROL PANEL

BLOCK ACCESS CONTROL PANEL

Block C Entrance CCTV Camera Block B Main Entrance

GATES ACCESS CONTROL PANEL

Block C Entrance CCTV Camera Block C Main Entrance Door 1

Block C Main Entrance Door 2

Block D Main Entrance

Block B Rear Gate

Front Vehicle Gates

BLOCK A FRONT ENTRANCE

BLOCK A STAIRS

PROXIMITY DEVICE LINKED TO BLOCK A LIFT

BIN STORE A

BIN STORE B

CYCLE STORE

FRONT PEDESTRIAN GATE

FRONT VEHICLE GATE (ACCESS/EGRESS VIA REMOTE/PROXIMITY DEVICE AND GROUND LOOP

BLOCK B FRONT ENTRANCE

BLOCK B STAIR/LIFT LOBBY

BLOCK C FRONT ENTRANCE No.1

BLOCK C STAIR/LIFT LOBBY DOOR 1

BLOCK C STAIR/LIFT LOBBY DOOR 2

BLOCK C FRONT ENTRANCE No.2

BLOCK D FRONT ENTRANCE

BLOCK D STAIR/LIFT LOBBY

BLOCK D REAR GATE

DUCTED CONNECTIONS BETWEEN MAIN CONTROLLER FOR FRONT PEDESTRIAN GATES BLOCKS B,C & D

DOOR KEY ENTRY SYSTEM

The main access to the development for visitors on foot will be via the pedestrian

Handsets complete with an LED display to enable people with hearing impairment

All residents will be provided with access control proximity fobs, with this fob they

Each dwelling shall be provided with 2No. door entry fobs, pre-programmed for the

entrance gates, visitors for flats will dial the number of the intended flat on the

to use them and a single push button release of the entrance phone keep.

will have access to the pedestrian entrance gates and main entrance door for the

areas they require, the residents fobs should only be programmed to allow access

Handsets are to be located within halls of each of the dwellings 1200 mm above

core and ancillary areas where their dwelling is located only ie bin/cycle stores.

to the areas they require. Master suiting of the system however should ensure

There is to be a proximity reader system fitted around the building as detailed on

system has been installed.

the external ducts and internal ELV tray and taken into each dwelling, providing a handset to each.

Once through the gate. the visitor will proceed to the relevant block and call the flat again via the door entry panel at the main front entrance door, again the

The speech grille of the entrance phone panels are to be set approximately

the drawings that will enable entry to an authorised user by recognition of a

resident will 'buzz them in' and allow entry to the building. A fob access system will

1100mm above the level of the adjacent external paving.

pre-programmed fob without the use of a key or other mechanical device. Once

In addition to the provision of equipment to enable future programming by the

the authorised user has passed through the door, the locking system is to

Employer, the Contractor shall also include for additional 30No. blank fobs ready

The Contractor to be responsible for the maintenance of the entrance phone

automatically re-engage preventing further access without another authorised fob

for programming. Provide details for obtaining further fobs if required at a later

system for the duration of the defect liability period and to provide the Employer

or via internal lock release (entry phone release or push button).

date and to allow for training the Employer or Employer's Agent in the operation

prevent visitors from advancing further into the building than the entrance lobby, The entry point shall be confined to the main entrance door(s)/ gates / block(s) serving all dwellings and shall be wired into the Landlord's supply, refer to

that the Employer's fobs can also be used to access other blocks in which the

finished floor level, in positions as shown on the dwelling layout drawings.

The electrical services contractor shall supply, install and commission a video door entry / fob access control system in all parts of the building and in all blocks via

How the system will work for residents

How the system will work for visitors

therefore, the tenant will be required to come down to the entrance floor to accompany visitors to their dwelling.

and programming of the system.

with a copy of the maintenance agreement at handover.

schematic for further details. The system shall comprise of the following principal elements: The system shall be programmed and work in the following way: 1. A recessed entrance phone panel suitably weathered and containing The entry / access control will consist of colour video entry with 2 way speech, and

illuminated push buttons of sufficient number to reflect the number of units

Provide the Employer with a quotation for the continued maintenance cover for the

further lobby door inside the building to prevent further progress into the building

How the system will work for vehicles

12 months following the Defects Liability Period that quotation to be provided at

past the stairs/lift without an authorised fob. In block A where the lift is utilised to

The vehicle access system will work as a separate entity without any interface to

the end of the Defects Liability Period.

access the cycle store, a proximity device will interfaced to the lift so that tennants

the main access control system. All residents allocated a parking space will be

from other blocks wishing to access the cycle store can only advance between the

provided with an access control proximity fob/remote control, with this device they

lower ground and ground floors.

will have access to the front vehicular gate, egress from the site by vehicle will be

fob access control for residents. The entrance panel(s) will be stainless steel and

the system is serving, LED display to enable people with hearing impairment

consist of a digital keypad with display and fob reader (controlled doors to be fitted

to use them, and having a vandal resistant stainless steel face plate and a

How the system will work for emergency services

flange box.

In the event of a fire signal in the communal area of an individual block, an

with mag-locks), visual recognition will be achieved via a separate mini dome colour CCTV camera suitably positioned for facial recognition of visitors. The system will be also be linked with AOV/Fire Alarm system to release doors in event

A Tradesmen's button is not required.

of an activation panel fixed with security hidden screws.

the main access control system. All residents allocated a parking space will be

3. Colour mini-dome cameras at each main entrance panel.

will signal the doors to fail safe and all locking devices will disengage for the

release' button located internally adjacent to the door it serves. This will release

Project

the locking system to allow exit and will then automatically re-engage the lock

Union Road - Union Road, Clapham Road, Clapham SW4

after a suitable time delay to prevent unauthorised access.

Title

At each of the main gates, a fireman's drop switch will be located to allow the The proximity reader system must be capable of being operated by the Employer following handover, with the Employer having the ability to programme

will have access to the front vehicular gate, egress from the site by vehicle will be

4. An electronically operated keep/maglock.

be located within block A, a data connection is to be allowed in order for off site administration of the system to be carried out.

via a buried induction loop provided as part of the gate package

INIT CHKD

Client

respective block.

replacement fobs or delete existing fobs. The master panel linking to all others to

provided with an access control proximity fob/remote control, with this device they

DATE

Each door fitted with the proximity reader system is to be fitted with a 'push to

emergency services to get into the building.

The vehicle access system will work as a separate entity without any interface to

via a buried induction loop provided as part of the gate package

DESCRIPTION

interface between the smoke detection system and the block access control panel

2. The panel to incorporate an integral two-way speaker and suitably protected HHow the system will work for vehicles

REV

In each block a proximity device will be located at the main main door and at a

AS BUILT

PERFORMACE SPECIFICATION

Security Schematic - Door Entry Schematic Scale

Date

Drawn By

Checked By

Project No:

Drawing No:

Revision

NTS

24.07.2013

TE

CH

K130121

ES006

C2

St John's House, 1A Knoll Rise, Orpington, Kent BR6 0JX T 01689 888222 F 01689 888299 E [email protected] calfordseaden LLP is a Limited Liability Partnership Registered in England & Wales number OC315838

5.

Multi-core communication cable to the required standards.

ORPINGTON

LONDON

BIRMINGHAM

WINCHESTER

www.calfordseaden.co.uk