[PDF]Plot 10 Union Road, Clapham - Rackcdn.comc24110ab053e5c234c6f-9b7150e100ab604df0aafbaf58c9fe02.r58.cf3.rackcdn.com/...
3 downloads
178 Views
74KB Size
BUILDING LEAKAGE TEST HPD Building Compliance Ltd Cherry Tree House High Street Thorndon, Suffolk IP23 7LX Phone: 01379 678092
Date of Test: 24th February 2015 Test File: Plot 10 Union Road, Clapham Customer:
Technician: David Taylor (BINDT Reg. 0276)
Durkan Limited Building Address: 4 Elstree Gate Elstree Way Borehamwood, Hertfordshire WD6 1JD Phone: Fax:
Test Results at 50 Pascals: V50: Airflow (m³/h) n50: Air Changes per Hour (1/h) w50: q50: m³/(h*m² Surface Area)
Block B, Type B2 Plot 10 Union Road Clapham, London SW4 6JP
381 ( +/- 0.6 %)
2.37
Leakage Areas:
129.0 cm² ( +/- 3.8 %) Canadian EqLA @ 10 Pa or 0.80 cm²/m² Surface Area 63.0 cm² ( +/- 6.0 %) LBL ELA @ 4 Pa or 0.39 cm²/m² Surface Area
Building Leakage Curve:
Air Flow Coefficient (Cenv) = 20.7 ( +/- 9.3 %) Air Leakage Coefficient (CL) = 20.9 ( +/- 9.3 %) Exponent (n) = 0.742 ( +/- 0.024 ) Correlation Coefficient = 0.99638
Test Standard: Type of Test Method: Equipment:
EN 13829 Test Mode: Depressurization B Regulation complied with: ADL1A 2010 Model 3 Minneapolis Blower Door, S/N 11812
Inside Temperature: Outside Temperature: Barometric Pressure: Wind Class: Building Wind Exposure: Type of Heating: Type of Air Conditioning: Type of Ventilation:
11 °C 9 °C 101325 Pa 3 Gentle Breeze Partly Exposed Building gas boiler to wet Rads
Volume: Surface Area: Floor Area: Uncertainty of Building Dimensions: Year of Construction:
161 m²
2% 2015
Central Extract
600 500 400 300 Building Leakage (m³/h)
200
100 90 80 70 60 50 4
5
6
7 8 9 10
20 30 Building Pressure (Pa)
40
50 60 70 80
BUILDING LEAKAGE TEST Page 2 Date of Test: 24th February 2015 Test File: Plot 10 Union Road, Clapham Comments Second floor flat Wet Rads Temp. seals to extractor registers Water in all traps DAP 3.0 Data Points: Depressurization Nominal Building Fan Pressure Pressure (Pa) (Pa) -0.3 n/a -63.0 162.3 -61.2 154.3 -55.4 138.0 -50.3 123.9 -45.0 101.4 -40.0 89.8 -35.6 67.0 -30.3 56.1 -25.1 44.6 -0.2 n/a Test 1 Baseline (Pa):
Nominal Flow (m³/h)
Temperature Adjusted Flow (m³/h)
% Error
455 443 418 395 356 334 287 261 232
449 437 412 390 351 330 283 258 229
-0.6 -1.1 0.5 2.1 0.0 2.6 -4.0 -1.2 0.9
p01- = -0.3
p01+ = 0.0
p02- = -0.2
p02+ = 0.0
Fan Configuration Ring C Ring C Ring C Ring C Ring C Ring C Ring C Ring C Ring C