pure water


Espresso Machines. Features. • Reduces lime scale build-up in ice machines. • Reduces maintenance—lower maintenance costs. • Better tasting ic...

2 downloads 146 Views 381KB Size

ES-WQ-PWSYS-FIL-ICE4

For Light Commercial Applications Job Name ––––––––––––––––––––––––––––––––––––––––––––

Contractor –––––––––––––––––––––––––––––––––––––––––––––

Job Location ––––––––––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––––

Engineer ––––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––––

Representative –––––––––––––––––––––––––––––––––––––––––

PURE WATER

Model PWSYS-FIL-ICE4 Light Commercial Ice Maker Filtration Systems Flow Rate: Maximum 4 gpm (15 lpm) The Model PWSYS-FIL-ICE4 has been engineered to address and correct multiple common water related problems both efficiently and economically in light commercial applications for ice machines and drink stations. Water for tea, coffee, and soft drinks is filtered by the triple filter. This filtered water then feeds the remote ice filters for dedicated treatment of the ice machine.

Applications • Ice Machines • Soda Machines • Tea Machines • Espresso Machines PWSYS-FIL-ICE4-2400-2

System Specifications Maximum Pressure: 125psi/8.6 bar Maximum Temperature: 100°F/38°C Inlet/Outlet Connections: 3⁄4" FPT with ½" FPT Maximum Flow Rate: 4 gpm

PWSYS-FIL-ICE4-2400-2 Max. Flow Rate: 4 gpm 1⁄ 2" FPT

OUT 3⁄ 4" FPT

IN

To Ice Maker

⁄" FPT 34

⁄ " O.P. Flush Line

14

Width 25 1⁄ 4" Depth 5 1⁄ 8" (Front to Back)

1⁄ 2" FPT

Height 13 1⁄4"

• Reduces lime scale build-up in ice machines • Reduces maintenance—lower maintenance costs • Better tasting ice and drinks • Easy to install • Simple filter replacement • In/Out valves allow for easy filter service • Gauges and flush kit included • Improves the taste of coffee, tea and soft drinks

Height 26 1⁄ 2"

Features

To Ice Maker Depth 43⁄ 4" (Front to Back)

Filter Cartridge Life Span Filter cartridges should be changed at 20,000 gallons, 15psi over all system pressure drop at normal flow rate, or 6 months. Whichever comes first.

Replacement Filters Model No.

Frequency

Description

PWFIL-SED-STD-10-20M-DEP 10" Sediment filter PWFIL-CB-STD-20-5M-8K 20" Carbon Block filter (2 required) PWFIL-PHOS-STD-10-24 10" Polyphosphate filter (2 required) Note: Water conditions may require more frequent cartridge replacement

Width 4 3⁄4"

Note: A  llow 3" of clearance at bottom of system for removal of filter bowls for filter cartridge replacement

Please note: Cartridge capacities are estimates and may be less depending on incoming water quality. Cartridges should be changed at least every 6 months. Note: Do not use with water that is microbiologically unsafe or

of unknown quality without adequate disinfection before or after the system.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

A Watts Water Technologies Company

ES-WQ-PWSYS-FIL-ICE4 1122

USA: North Andover, MA • Tel. (800) 224-1299 • www.watts.com Canada: Burlington, ON • Tel. (888) 208-8927 • www.wattscanada.ca

© 2011 Watts