[PDF]Range: 1W to 200 W Sensors for Laser Power and...
0 downloads
89 Views
1MB Size
Sensors for Laser Power and Position Sensing ABSORBERS
Range: 1W to 200 W Features: · High Beam Position Accuracy · Highest Power Density on SHC Coating · HPB coating is suitable for Excimer Lasers Model
QA-200-D40-HPB
QA-200-D40-SHC
Max. Average Power
200 W
200 W
Max. Intermittent Power (1)
250 W
250 W
1W
1W
Power Resolution
10 mW
10 mW
Noise Equivalent Power (NEP)
Min. Power
10 mW
10 mW
Response Time
2 sec
2 sec
Power Calibration Uncertainty
± 3%
± 3%
Power Linearity (2)
± 1%
± 1%
Beam Position Accuracy
100µm
100µm
Beam Position Resolution
100µm
100µm
1W
1W
40 mm
40 mm
SENSORS
Power Mode
Minimum Power (3)
MONITORS & SW
Beam Sensing Mode
Aperture
HPB
SHC
0.19 - 11 µm
0.19 - 11 µm
0.19 - 2.1 µm, 2.94µm, 9 - 11 µm
0.25 - 1.1 µm, 9 - 11 µm
Type Absorber Spectral Range Calibration Spectral Range Max Power Density (4) Max Energy Density
(4)
7 kW/cm² @200 W
28 kW/cm² @200 W
5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²
5ms pulse width: 115 J/cm² 10µs pulse width: 4 J/cm² 10ns pulse width: 1 J/cm²
Forced Air with Fan (a)
Forced Air with Fan (a)
USB/RS232 SENSORS
Absorber Specs
Cooling Weight Dimension
1.2 kg
1.2 kg
100 x 100 x 85 mm
100 x 100 x 85 mm
1.5 m - DB25
1.5 m - DB25
Light Duty Stand Included
Light Duty Stand Included
a). 12V DC Power Supply Included
a). 12V DC Power Supply Included
Cable lenght - connector Stand and Post
OEM SOLUTIONS
General Characteristics
Notes
POWER PROBES
(1). 2 minutes max (2). Detector centrally irradiated @50% of useful surface. (3). necessary for beam position sensing. (4). Damage thresholds also depend on power level. Please see damage graphs
QA-200-D40-HPB
QA-200-D40-SHC
Light Duty Stand
Via Burona, 51 - Vimodrone (Milano) - ITALY Ph: +39 02 27 40 02 36 Fax: +39 02 25 02 91 61 For latest updates please visit our website: www.laserpoint.eu
35
Sensors for Laser Power and Position Sensing ABSORBERS
Range: 10W to 3kW Features: · High Beam Position Accuracy · Water cooled heads to 3000 W · Corrosion-Proof Water-Cooled Sensors Model
QW-1500-D40-HPB
QW-1500-D40-SHC
QW-3000-D55-HPB
QW-3000-D55-SHC
Max. Average Power
1500 W
1500 W
3000 W
3000 W
Max. Intermittent Power (1)
2250 W
2250 W
4500 W
4500 W
10 W
10 W
20 W
20 W
Power Resolution
100 mW
100 mW
100 mW
100 mW
Noise Equivalent Power (NEP)
Power Mode
SENSORS
Min. Power
100 mW
200 mW
250 mW
250 mW
Response Time
4 sec
4 sec
5 sec
5 sec
Power Calibration Uncertainty
± 5%
± 5%
± 5%
± 5%
± 1.5%
± 1.5%
± 2%
± 2%
Beam Position Accuracy
100µm
200µm
300µm
300µm
Beam Position Resolution
100µm
100µm
100µm
100µm
Minimum Power (3)
7.5 W
7.5 W
15 W
15 W
40 mm
40 mm
55 mm
55 mm
HPB
SHC
HPB
SHC
0.19 - 11 µm
0.19 - 11 µm
0.19 - 11 µm
0.19 - 11 µm
0.19 - 2.1 µm, 2.94µm, 9 - 11 µm
0.25 - 1.1 µm, 9 - 11 µm
0.19 - 2.1 µm, 2.94µm, 9 - 11 µm
0.25 - 1.1 µm, 9 - 11 µm
2.4 kW/cm² @1 kW
7 kW/cm² @1 kW
1.8 kW/cm² @2kW
3.6 kW/cm² @2kW
5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²
5ms pulse width: 115 J/cm² 10µs pulse width: 4 J/cm² 10ns pulse width: 1 J/cm²
5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²
5ms pulse width: 115 J/cm² 10µs pulse width: 4 J/cm² 10ns pulse width: 1 J/cm²
Water (a)
Water (a)
Water (a)
Water (a)
Power Linearity (2)
POWER PROBES
OEM SOLUTIONS
USB/RS232 SENSORS
MONITORS & SW
Beam Sensing Mode
Absorber Specs Aperture Type Absorber Spectral Range Calibration Spectral Range Max Power Density
(4)
Max Energy Density
(4)
General Characteristics Cooling Weight Dimension Cable lenght - connector Stand and Post
1.1 kg
1.1 kg
2.3 kg
4.2 kg
Ø 116 x 44 mm
Ø 116 x 44 mm
Ø 148 x 55 mm
Ø 148 x 55 mm
5 m - DB25
5 m - DB25
5 m - DB25
5 m - DB25
Heavy Duty Stand Included
Heavy Duty Stand Included
Heavy Duty Stand Included
Heavy Duty Stand Included
Notes (1). 2 minutes max (2). Detector centrally irradiated @50% of useful surface. (a). Water 4 liter/min (@ 22°C); (a). Water 4 liter/min (@ 22°C); (a). Water 5 liter/min (@ 22°C); (a). Water 5 liter/min (@ 22°C); (3). necessary for beam position senadmissible rate of temperature admissible rate of temperature admissible rate of temperature admissible rate of temperature sing. variation < 1 °C/min variation < 1 °C/min variation < 1 °C/min variation < 1 °C/min (4). Damage thresholds also depend on power level. Please see damage graphs for more details
QW-1500-D40-HPB
QW-1500-D40-SHC
QW-3000-D55-HPB
Via Burona, 51 - Vimodrone (Milano) - ITALY Ph: +39 02 27 40 02 36 Fax: +39 02 25 02 91 61 For latest updates please visit our website: www.laserpoint.eu
QW-3000-D55-SHC
36
Sensors for Laser Power and Position Sensing ABSORBERS
Range: 30W to 6kW Features: · High Beam Position Accuracy · Water cooled heads to 3000 W · Corrosion-Proof Water-Cooled Sensors Model
QW-6000-D55-SHC
Power Mode Max. Average Power
6000 W
Max. Intermittent Power (1)
9000 W
Power Resolution
100 mW
Noise Equivalent Power (NEP)
500 mW
Response Time
3.5 sec
Power Calibration Uncertainty
± 5%
Power Linearity (2)
± 2%
SENSORS
30 W
Min. Power
Beam Position Accuracy
300µm
Beam Position Resolution
100µm
Minimum Power (3)
MONITORS & SW
Beam Sensing Mode
30 W
Absorber Specs 55 mm
Aperture
SHC
Type
0.19 - 11 µm
Absorber Spectral Range
Max Power Density
(4)
Max Energy Density
USB/RS232 SENSORS
0.25 - 1.1 µm, 9 - 11 µm
Calibration Spectral Range
4 kW/cm² @5kW 5ms pulse width: 115 J/cm² 10µs pulse width: 4 J/cm² 10ns pulse width: 1 J/cm²
(4)
General Characteristics Water (a)
Cooling
4.2 kg
Weight
OEM SOLUTIONS
Ø 148 x 55 mm
Dimension
5 m - DB25
Cable lenght - connector
Heavy Duty Stand Included
Stand and Post Notes
QW-6000-D55-SHC
(a). Water 8 liter/min (@ 22°C); admissible rate of temperature variation < 1 °C/min
POWER PROBES
(1). 2 minutes max (2). Detector centrally irradiated @50% of useful surface. (3). necessary for beam position sensing. (4). Damage thresholds also depend on power level. Please see damage graphs
Heavy Duty Stand
Via Burona, 51 - Vimodrone (Milano) - ITALY Ph: +39 02 27 40 02 36 Fax: +39 02 25 02 91 61 For latest updates please visit our website: www.laserpoint.eu
37