Redefining flexible riser integrity management - Innospection


[PDF]Redefining flexible riser integrity management - Innospectionwww.innospection.com/images/PDF/flex/FlexIQ%20Flyer.pdfCachedtools in the arena of f...

0 downloads 91 Views 2MB Size

Redefining flexible riser integrity management • Best in class inspection and computational simulation • Accurate damage detection and impact on design life • Improved understanding of operational risk • A fully integrated service for inspection, analysis, and data management

Bottom line: we deliver insight, not just data

Integrating FLEXASTM and MEC-FIT TM for Flexible Riser Integrity

Improving risk assessment. Increasing operational confidence.

A strategic alliance of industry leading inspection and simulation tools in the arena of flexible riser integrity management.

INSPECTION PLANNING

A COMPLETE OFFERING • Risk-based integrity management

FLEXAS™ DESIGN

and inspection planning

• State-of-the-art annulus testing

ANNULUS TESTING

FLEXIBLE INTEGRITY MANAGEMENT

• Visual and MEC-FIT™ (Magnetic Eddy Current) inspection

OUTER SHE ATH FABRIC TAPE

• Dynamic riser simulation using detailed, multilayered finite element models with FLEXAS™

OUTER TENSILE ARMOUR

INTERVENTION AND INTEGRITY MANAGEMENT

ANTI-WE AR TAPE

MEC-FIT™ FLEXIBLE RISER INSPECTION

INNER TENSILE ARMOUR

• Intervention planning and construction management

ANTI-WE AR TAPE PRESSURE ARMOUR

• Life of field riser analysis and model updates

INTERNAL SHE ATH

C ARC ASS

FLEXAS™ SIMULATIONS

ARMOR WIRE DEFECT IDENTIFICATION

DATA REPORTING

MEC-FITTM

• Combined DC magnetic and eddy current fields to detect single or multiple wire damage in up to 3 metallic layers

FLEXASTM

• More realistic simulations leading to increased accuracy for fatigue life predictions

• Capable of detecting cracking, pitting, general corrosion,

• Single integrated flexible riser global analysis

• Mapping wire layers and identifying details of individual findings • No requirement for annulus to be flooded • Deployment from topside or ROV

• Elimination of secondary local stress analyses with

and wire misalignment and gaps

ANNULUS TESTING

• Positive pressure annulus test and riser vent path assessment • Temperature calibrated for accuracy • Gas sampling for corrosion assessments • Secondary volumetric flow meter digital readout • Improved quick connect kit to reduce pressure loss and eliminate leak paths

with detailed multi-layer models and direct stress recoveries detailed segment models

VALIDATION

❒❒ Deepstar qualification program ❒❒ Independent operator experimental benchmarking

❒❒ Selected by NASA and qualified for missioncritical analysis for manned space flight

Stress Time History for Individual Armour Wires

WWW.INTECSEA.COM

WWW.INNOSPECTION.COM

[email protected]

[email protected]