research & development


[PDF]research & development - Rackcdn.com8032c1fb3d623963968f-392426bfe23e9ffecbdfd263ee200e67.r75.cf1.rackcdn.com/...

2 downloads 129 Views 477KB Size

HEAD JAMB 12

6

13

NAILING FIN METHOD

JAMB 7

6" MAX JAMBS/HEADER

2 1 1/2" MAX

1

18" MAX JAMBS/HEADER

5

4" MAX 3 JAMBS/HEADER

12

6 2

7" MAX JAMBS/HEADER

8 9

3

9 7 8 1/2" MAX

NOTES: 1. FOR GENERAL SPECIFICATIONS, REFER TO DOC 00003952 2. THIS PRINT IS FOR STRUCTURAL PERFORMANCE ONLY; FOR FLASHING & SEALING INSTRUCTIONS, REFER TO THE INSTALLATION INSTRUCTIONS 3. SHIMS: - PLACE SHIMS WITHIN 4" - 6" OF EACH CORNER AND SPACE ALL OTHERS EVENLY AT A MAXIMUM OF 15" APPART. - PLACE SHIMS AT EACH LOCATION WHERE INSTALLATION SCREWS PASS THROUGH JAMBS/ HEAD JAMB. 4. IF CHEMICALLY TREATED LUMBER IS USED FOR FRAMING MATERIAL, FASTENERS INTO THE FRAMING MUST BE A MINIMUM OF 0.90 OZ/FT^2 ZINC HOT DIPPED GALVANIZED OR STAINLESS STEEL TYPE 304 OR 316. 5. INSTALLATION HOLE THROUGH SILL IS PRE-DRILLED 6. APPROVED PRODUCTS: FL14133

SILL

UPDATED FLORIDA NUMBER UPDATED ASSEMBLY (UNIT AND SECTION GLASS) UPDATED BOTTOM RAIL PROFILE UPDATED FLORIDA NUMBER ADDED CROSS SECTIONS, NAILING FIN 2.1 INSTALLATION NOTE, NOTES 3,4,5 6 2.0 UPDATED FLORIDA NUMBER DESCRIPTION / REQUESTOR REV

1

13 4

11

10

6

NAILING FIN INSTALLATION -APPLY INSTALLATION CLIP TO UNIT ALONG HEAD JAMB AND JAMBS FASTEN WITH TWO #7X .625 WOOD SCREWS. SPACE PER ELEVATION. -APPLY MULL CLIP TO MULL JOINTS AT HEAD JAMB -FASTEN WITH #7 X .625" WOOD SCREWS INTO IOFD LABELED HOLES -APPLY 5/16" BEAD OF APA RATED AFG-1 SPEC C290 CONSTRUCTION ADHESIVE TO BOTTOM OF SILL -ATTACH INSTALLATION CLIPS TO FRAMING WITH THREE 1.25" CONSTRUCTION SCREWS. SPACE PER ELEVATION -SECURE NAILING FIN WITH 2" GALVANIZED ROOFING NAILS, MINIMUM OF TWO PER SIDE. SPACE PER ELEVATION. -ANCHOR THE SILL AT THE CENTER WITH A #10 X 2.75" SHEET METAL SCREW. FOR CONCRETE CONSTRUCTION, USE A 3/16" X 2.75" MASONRY SCREW -FASTEN #8 X 2.500" INSTALLATION SCREWS THROUGH BOTTOM AND TOP INTERIOR HOLES IN EVERY HINGE AND THROUGH TWO INTERIOR HOLES AT HEADER STRIKE. FASTEN INSTALLATION SCREW THROUGH JAMB STRIKE ON X UNITS ONLY -INSTALLATION SCREWS ARE NOT REQUIRED ON STATIONARY UNITS. 2.5 2.4 2.3 2.2

2

16890 16890 16890 16890

01/20/14 08/01/13 05/22/13 02/01/13

SAL AKN CAF WAG

16890

11/05/12

WAG

16890 02/17/12 AKM ECN NO DATE REV BY

7

SCALE 1:3

4 13 12 11 10 9 8 7 6 5 4 3 2 1 ITEM

NA NA NA NA 00003212 NA NA NA 00067877 -

APA RATED CONSTRUCTION ADHESIVE 1.250" CONSTRUCTION SCREW FLOORING SILL NOSE SUPPORT #7 X .625 SCREW SHIMS FRAMING MATERIAL SHEATHING IOFD INSTALLATION MULL CLIP 3/16" X 2.75" MASONRY SCREW - 11800869 2.00" GAL ROOFING NAIL 00052256 INSTALLATION CLIP 00003228 #8 X 2.500" PH, PH, SCREW DWG NO DESCRIPTION PARTS LIST

RESEARCH & DEVELOPMENT WARROAD, MN, USA, (218) 386-4021

Windows and Doors

PRODUCT CATEGORY: UNIT TYPE:

INTEGRITY WOOD ULTREX IOFD

DWG TYPE: INSTALLATION DESCRIPTION: IOFD+IOFD IMPACT ELEVATION FL 14133 CHK: SIZE: CLASS: DWG NO: 00069401 B MISC APP: SCALE: DATE: DWG BY: SHEET: DAWKINS, ANDY 1:15 04/28/10 1 OF 1

Template Version 10.3 NOTICE - CONFIDENTIAL INFORMATION The information in this document is privileged and strictly confidential. The information contained herein shall be used only by Marvin Windows and Doors employees and by those agents or suppliers granted official written permission. If the reader of this document is not the intended recipient, or the employee or agent of the intended recipient, please delete this document from all data storage devices, and destroy all hard copies. Any unauthorized dissemination, distribution, copying or other use of the information contained in this document is strictly prohibited.

Installation Clips with Nailing Fin NOTE: Installation and mull clips are specialized for each frame/mull. Casement Polygons and Round Tops use ICA / ICAP / ICAWN clips. Double Hung, Glider, and Door Polygons and Round Tops use IOFD clips. MULLING: Direct Glaze Polygons mulled to ICA /ICAP/ICAWN use ICA mull clip. Direct Glaze Polygons mulled to ITDH / ITDHP / IOFD use IOFD mull clip. 1. Attach clips to the unit jambs and head jamb (and sill for Round Tops) with #7 x 5/8Ǝ wood screws 6Ǝ (152) maximum from each corner and 18Ǝ (457) maximum around the unit perimeter. Center mull clip over mullion. Attach to unit and mull post with #7 x 5/8Ǝ wood screw through every hole in mull clip. Attach nailing fin 4Ǝ (102) from all corners and a maximum of 7Ǝ (178) apart around the rest of the unit perimeter. See “Installing the Window or Door” on page 3 for more details on how to fasten the unit in the opening with the various installation clips. 2. On Round Top Double Hung units, attach 5/8Ǝ X 3 1/2Ǝ filler blocks to the sill prior to attachment of installation clips. Attach blocks by first placing a 5/16Ǝ(8) bead of construction adhesive to the block. Fasten the blocks to the sill using #8 x1 1/4Ǝ screws. 3. When using installation and mull clips with nailing fin, use the screw holes in the clip as a guide and drill through the nailing fin with a 1/8Ǝ (3) drill bit. This will give you the location of the screw holes when you fasten the unit to the rough opening. 6" (152)

18" (457)

ITDH

IOFD/IRT DH

ICA/ICAP/IAWN/IRT CA

ISFD Pre-drill with a 1/8" drill bit through nailing fin

Mulled Units Screws

Figure 2 Fastening and Spacing Methods, Structural Brackets or Installation Clips with Nailing Fin 2014-01-15 19971049

2

Integrity Windows and Doors Instruction for IZ3 Rated Products

Installing the Window or Door 2. When using installation and mull clips in conjunction with nailing fin, fasten the clips to the rough opening with #8x1 1/4Ǝ screws. See figure 5.

1. All impact rated windows and doors (except Round Tops) must be adhered to the sill with a discontinuous 5/16Ǝ (8) bead of construction adhesive on the framing sill where it will contact the window or door frame sill See figure 3. Leave approximately 2Ǝ (51) gaps on the ends. See figure 4.

Roofing nails

Construction adhesive

#8 x 1 1/4” screws

Figure 5 Fasten clips through nailing fin.

3. When using structural and mull brackets, bend brackets against wood framing as shown in figure 6. Attach structural brackets to wood framing with two #8 x 1 5/8Ǝ screws, making sure that the screws are no more than 1/4Ǝ(6) from the bend in the bracket (edge of the wood buck). Angle the screws approximately 15° toward the thicker part of the framing member.

Figure 3 Adhere sill of window to the sill of opening.

Gaps at ends

Shim

1/4" 5/32" holes #8 x 1 5/8“screws

Figure 4 Discontinuous bead of construction adhesive.

NOTE: Use APA rated AFG-01 spec, construction adhesive. Make sure the adhesive is compatible with all building materials and the unit frame.

Figure 6 Fastening with structural brackets (concrete block application shown from interior).

4. Follow all finishing, flashing and sealing steps found in the installation instructions sent with your window or door order. For Casement mulled units, follow the instructions in, “Additional Fastening for Casement Mull Installations” on page 4.

2014-01-15 19971049

3

Integrity Windows and Doors Instruction for IZ3 Rated Products