SCOPE OF WORK OUTLINE 1. General Tower Location and Description Primary Towers (8)SEPTA owned inspections & maintenance Name
Address
Type of Tower
ROX
600 Port Royal Rd. Phila., Pa. 19128
382 ft. tower, self supporting, ground access
Wyoming
200 W. Wyoming Ave. Phila., Pa. 19140
100 ft. tower on top of a 20 ft. bldg., supported by guide wires, roof top
Oxford Valley Mall
2300 E. Lincoln Hwy. Langhorne, Pa. 19047
60 ft. tower on a 95 ft. bldg., roof top tower
Victory Ave.
110 Victory Ave. Upper Darby, Pa. 19082
180 ft. self supporting Rohn tower and foundation, ground access
Bridge Tower
1509 Bridge St. Phila., Pa. 19124
80 ft. tower, self supporting, ground access
(A) Tower
Airport, off of 61st & Eastwick Ave., Phila., Pa. 19142
90 ft. tower, self supporting, ground access
Villanova
800 Lancaster Ave. Villanova, Pa. 19085
40 ft. self supporting tower, ground access
Hughes
464 Yerkis Lane King of Prussia, Pa. 19406
80 ft. Rohn SSV, self support, ground access
Other Towers (4) Non-SEPTA owned, inspections & maintenance
Bacton Hill
2001 Bodine Rd. Malvern, Pa. 19355
240 ft. tower, ground access
Y-100
407 Bishop Hollow Rd. Newtown Sq., Pa. 19073
1000 ft. tower, ground access
Lowes PSFS
1200 Market St. Phila., Pa. 19107 (32nd fl. Penthouse)
200 ft. tower, roof top, 34 story bldg.
New Britian
60 Old Limkiln Rd. & Ferry Rd. Doylestown, Pa., 18901
300 ft. tower, ground access
SCOPE OF WORK OUTLINE Cont.d 2. GENERAL All towers to be inspected once a year. Towers shall be inspected for mechanical/structural soundness and to ensure that they remain in compliance with FCC and FAA requirements. 3. SEPTA TOWER INSPECTION-MAINTENANCE & REPAIR In additon tower inspections at SEPTA owned towers, the contractor needs to provide labor and materials needed on SEPTA or Non-SEPTA towers in the event of planned or unplanned failures, or maintenance which include lighting, wind, moisture, corrosion, age and any other damages. Contractor will also repair and/or replace any defective component on any radio system(s), which include antennas, cables, connectors, clamps, brackets, etc. At anytime contractor must be available for emergency service (24/7). 4. Lamp/Strobe Replacement The bidder shall supply prices for materials that SEPTA would be charged for should SEPTA call upon the contractor during the calendar year to replace lamps. One price shall be provided for the replacing side and top lamps (where applicable). The price is to include replacement lamps and labor. 5. WRITTEN REPORTS Upon completion of each inspection, the bidder shall submit 3 written reports along with a soft copy report to SEPTA's radio system managers listed below. This report shall include photos, a description of the physical condition of the towers, all lighting and markings, and any work the inspector advises to be done. If it is advised that work is needed on a tower contractor shall itemize each task with cost of material and labor for each tower site. The report should also include a list of all work performed by the contractor, as will as any changes to the tower since the last inspection, including recently installed antennas. The reports and invoices shall be submitted to the below no later than 14 days after each inspection. Robert Lannon/Lou Dibonaventura Radio Systems Managers Southeastern Pennsylvania Transportation Authority 200 W. Wyoming Avenue Philadelphia, PA 19140