SPEAKMAN ALEXANDRIA™ Shower Combination SM-6430-P & SM-6410

SPECIFICATION

FEATURES: • Traditional style • S-3011 showerhead • S-2500 shower arm & flange • SM-6400-P pressure balance shower valve with diverter & trim ❑S  M-6430-P with S-1559 diverter tub spout with slip-fit connection ❑ SM-6410-P without S-1559 diverter tub spout

COMPLIANCE: • Certified to ASME A112.18.1/CSA B125.1 and ASSE 1016 standards

AVAILABLE FINISHES: ADD SUFFIX TO MODEL #

• Polished Chrome (standard) • Brushed Nickel 1”(25mm) DIA HOLE FOR SHOWER ARM

❑ -BN

WARRANTY: • 1 year limited

6’-6” (2 Meters) TO FLOOR 5-1/2” (140mm)DIA HOLE FOR VALVE MOUNTING PLATE HOT WATER INLET

SHOWER OUTLET

FINISHED WALL COLD WATER INLET

TLS PLATE TUB OUTLET 1/2” NPT FEMALE, PLUG PROVIDED

LEVER HANDLE WALL PLATE 7” DIA (178mm)

1/2” (13mm)

5-3/4” (146mm)

4” (102mm) TO TOP OF TUB

1”(25mm) DIA HOLE FOR TUBE SPOUT

4-15/16” (125mm)

DIVERTER

INTEGRAL STOPS W/ FEMALE INLETS FOR 1/2” COPPER WATER TUBE 1’9” (533mm) SEE NOTE #3

3-1/2” (89mm)

TUB SPOUT, 1/2” COPPER TUBE CONNECTION

2-1/2” TO 3-1/2” (64 - 89mm)

6-1/8” (156mm) NOTE: 1. All dimensions are in inches (millimeters) unless otherwise specified and are subject to change without notice. 2. Unless otherwise specified, all inlets and outlets are ½” female copper sweat. 3. For ADA mounting locations, consult ADAAG, ANSI A117.1, or static regulations

NOTES: 1. ALL DIMENSIONS ARE IN INCHES (MILLIMETERS) UNLESS OTHERWISE SPECIFIED THIS SPACE ARCHITECT/ENGINEER APPROVAL. AND ARE SUBJECT FOR TO CHANGE WITHOUT NOTICE. 2. UNLESS OTHERWISE SPECIFIED ALL INLETS AND OUTLETS ARE 1/2” FEMALE COPPER SWEAT. 3. FOR ADA MOUNTING LOCATIONS CONSULT ADAAG, ANSI A117.1, OR STATE REGULATIONS.

400 ANCHOR MILL ROAD | NEW CASTLE, DE 19720 P: 800-537-2107 | F: 800-977-2747 W W W. S P E A K M A N C O M P A N Y. C O M 92-3416

REVISION DATE: FEB. 2012