Unit Start--Up Checklist


[PDF]Unit Start--Up Checklist - Rackcdn.com9459a8a7c04856c345d2-4f8300507cf0a318260a6776e1a92a67.r99.cf1.r...

10 downloads 124 Views 38KB Size

Geothermal Heat Pumps

Unit Start--Up Checklist Remove from literature packet and place in customer file at dealership after completion. NOTE: Read the entire installation instruction manual before starting the installation and start---up procedure.

Date:__________________________________ Customer Name: Address:

City, State, Zip Phone: Start---Up Technician Name:

Unit Nameplate Data

Model #:

Serial #:

Refrigerant Charge (oz): Compressor

RLA:

LRA:

Blower Motor FLA (Or NPA):

HP:

Maximum Fuse Size (amps):

Maximum Circuit Ampacity:

1

Operating Conditions COOLING MODE

HEATING MODE

/

/

/

/

Entering / Leaving Air Temp Entering Air Measured at: Leaving Air Measured at: Source Fluid Type: Entering / Leaving Fluid Temp:

Calculate Heat of Extraction / Heat of Rejection and compare to performance tables shown in Product Data Heating Mode --- Heat of Extraction: Flow Rate (gpm) ____________ X Temp Difference (deg. F) __________ X Fluid Factor* __________ = __________ Cooling Mode --- Heat of Rejection: Flow Rate (gpm) ____________ X Temp Difference (deg. F) __________ X Fluid Factor* __________ = __________ * Fluid factor: Use 500 for water, 485 for antifreeze. Fluid Flow (gpm) Fluid Side Pressure Drop Compressor Volts / Amps:

/

/

Blower Motor Volts / Amps:

/

/

The following items are required for Troubleshooting ONLY. Do not install gauges unless a problem is suspected: Suction / Discharge Pressure (psig)

/

/

Suction / Discharge Temp

/

/

Suction Superheat Entering TXV / Cap Tube Temp Liquid Subcooling

Auxiliary Heat Model #:

Serial #:

Max Fuse Size (Amps):

Volts / Amps:

Entering Air Temperature:

Leaving Air Temperature:

8---733---940---361 (06/15) ECAC/BDP 7310 W. Morris St. Indianapolis, IN 46231

Edition Date: 08/15

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

2

Catalog No. CLGEO---02 Replaces: CLGEO--- 01